1-17-2. F-Series items

ITEM
No.
ITEM
F01
AUDIO NR IN SP
MODE
F02
EMERGENCY TAPE
PROTECTION
F13
TRACKING
CONTROL VIA
SEARCH DIAL
F16
DEVICE TYPE
MODIFY:0H
PROCESS CONT VR [0]
F21
LOCAL ENABLE
DNW-A220
DNW-A220P
DATA
Description
No.
DATA
[0]
[on]
n
1
switch select
This item is used exclusively for analog Betacam longitudinal audio playback
adjustment for 625/50 system
After adjustment is completed, return to the factory setting "0: on"
Turns on and off the Dolby NR when using a metal tape
0:
Dolby NR is turned on usually
1:
Dolby NR is turned on and off depending on the setting of the sub LCD menu
(in Audio setting page)
n
When using an oxide tape, follows the sub LCD menu setting regardless of the
above setting
[0]
[enable]
n
1
disable
This item is used exclusively for servo and mechanical adjustment
After adjustment is completed, return to the factory setting "0: enable"
Selects whether emergency tape protection operation is enabled or not when VTR
detects error in tape transport mechanism
0:
Tape protection operation is enabled
1:
Tape protection operation is disabled
[0]
[off]
n
1
on
This item is used exclusively for video tracking adjustment
After adjustment is completed, return to the factory setting "0: off"
Turns on and off the tracking control operation with SHUTTLE dial
0:
Tracking control with SHUTTLE dial is not activated
1:
Tracking control becomes active when turning SHUTTLE dial in PLAY mode
[0000] [0]
Determines response data to 9-pin remote command DEVICE TYPE REQUEST
0001
1
(00h, 11h)
|
|
0000:
FFFF FFFF
Except 0000: Returns the set values as they are:
n
Any selection of the above does not influence the whole VTR operation including
TTP
If this item is set to values other than the factory-setting (DATA:0000), the
operation of the unit is not ensured under the 9-pin remote command control.
[off]
Selects whether PROCESS CONTROL VR and sub LCD menu setting
1
on
(in Video setting page) are enabled or not, when LOCAL DISABLE command is
received through the 9-pin remote connector or the setup menu "006: LOCAL
FUNCTION ENABLE" is set to "all disable"
0:
Settings of PROCESS CONTROL VR and sub LCD menu are disabled
1:
Settings of PROCESS CONTROL VR and sub LCD menu are enabled
Returns the original device type data of the unit
The higher-order two digits are for DATA-1
The lower-order two digits are for DATA-2