4 Configuring the anybus device
4.4.1 Configuring an external controller using Siemens Step7 PC tool
Continued
4
5
6
7
8
Continues on next page
30
Action
Select Use IP parameters and enter the
IP address and subnet mask and then
click Assign IP configuration.
Enter device name in the Device name
text box and click Assign name.
For more information about the other
settings, see Siemens documentation.
Note
The IP address and device name must be
unique on the industrial network.
Click Close.
Open the project to which the PROFINET
Fieldbus Adapter should be added.
Open HW Config for the selected master.
On the Option menu, click Install GSD
File.
The GSDML file for PROFINET Anybus
Device must be imported from the Robot-
Ware DVD.
© Copyright 2008-2016 ABB. All rights reserved.
Note
xx0800000200
xx0800000188
Application manual - PROFINET Anybus Device
3HAC050968-001 Revision: C