ABB DSQC1000 Applications Manual page 20

Profinet anybus device
Table of Contents

Advertisement

2 Hardware overview
2.1 Main computer DSQC1000
Continued
Illustration, PROFINET anybus device DSQC 688
xx0800000136
NS
MS
LINK
PROFINET IO
LEDs
This section describes the LEDs of the PROFINET anybus device.
A test sequence is performed on the network status LED and on the module
status LED during start of the PROFINET anybus device.
Network status LED
LED status
OFF
Green
Green, flashing
Module status LED
LED status
OFF
GREEN
GREEN, 1 flash
GREEN, 2 flashes
RED
RED, 1 flash
RED, 2 flashes
RED, 3 flashes
RED, 4 flashes
Continues on next page
20
Network status LED
Module status LED
Link/Activity
RJ-45 connector
Note
Description
Offline
Online (RUN)
Online (STOP)
Description
Not initialized
Normal operation
Diagnostic event(s)
Blink
Exception error
Configuration error
IP address error
Device name error
Internal error
© Copyright 2008-2016 ABB. All rights reserved.
Comments
No power
No connection with a master
Connection with master established
Master in RUN state
Connection with master established
Master in STOP state
Comment
Module not configured or no power.
Module is initialized.
Diagnostic event(s) present.
Used by external configuration tools to identify
the node on the network.
Module in exception state.
Expected Identification differs from real identi-
fication.
IP address not set.
Device (Station) name not set.
Module has encountered a major internal error.
Application manual - PROFINET Anybus Device