Summary of Contents for National Instruments FieldPoint FP-1600

  • Page 1 (217) 352-9330 | Click HERE Find the National Instruments FP-1600 at our website:...
  • Page 2 fpoint cd.qxd 11/13/00 1:23 PM Page 1 FP-1600 FieldPoint Quick Start Guide What You Need to Get Set Up · Network Module · Power Supply · Mounting Hardware (DIN rail · FieldPoint Software CD or panel mount accessory) · Accessories: Ethernet cable, ·...
  • Page 3: Panel Mount

    fpoint cd.qxd 11/13/00 1:23 PM Page 2 DIN Rail Mount Panel Mount NOTE: Do not use spliced DIN B. Snap panel mount accessory rails. Use only a single DIN rail. (which you can order separately) onto module. B. Hook lip on back of module onto top of DIN rail, press down, and snap into place.
  • Page 4: Din Rail Mount

    fpoint cd.qxd 11/13/00 1:23 PM Page 3 Install the Terminal Base(s) CAUTION: Terminal bases must be connected to the network module before applying power to the module. Do not connect or disconnect terminal bases while power is applied to the network module. DIN Rail Mount Panel Mount A.
  • Page 5 fpoint cd.qxd 11/13/00 1:23 PM Page 4 DIN Rail Mount Panel Mount C. Slide into position and lock the rail D. Repeat for each terminal base, up to clip. Be careful not to bend any pins. nine for each network module in most cases.
  • Page 6: Install The I/O Module(S)

    fpoint cd.qxd 11/13/00 1:23 PM Page 5 Install the I/O Module(s) It does not matter where you install each I/O module, except for these types of situations: · · · · If you plan to cascade power between any I/O modules using the V and C terminals, those modules should be grouped together.
  • Page 7 Do not use a cable longer than 100 m. If you are using a 100 Mbps Ethernet, National Instruments recommends using a Category 5 shielded twisted-pair Ethernet. If you need to build your own cable, refer to the FP-1600 User Manual for cabling details.
  • Page 8 fpoint cd.qxd 11/13/00 1:23 PM Page 7 CAUTION: Cascading power from neighboring bases or network modules defeats isolation between cascaded modules. Separate Power Supply (Recommended) No External Cascaded Power Power Required (Reduces Isolation) FP-1600 FP-AI-100 FP-AO-200 FP-RLY-420 FP-TC-120 Power Supply Power Supply 15 16 V CAUTION: Cascading...
  • Page 9 fpoint cd.qxd 11/13/00 1:23 PM Page 8 Connect to Field Devices Use each I/O module’s operating instructions, or the diagram under its removable label, to help you connect your field devices. FP-AI-110 8 Channel, 16-Bit Analog Input Module Highlights FP-AI-110 To Power Overview Supply...
  • Page 10 After the hardware is installed, you should verify communication, configure the modules, configure your power-up states and watchdog settings. If you are using National Instruments FieldPoint software for these tasks, continue to the following section. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 11 11/13/00 1:24 PM Page 10 Install the FieldPoint Software A. Close all other applications. If you plan to install National Instruments development software such as Lookout, LabVIEW, or Measurement Studio, install them before you install the FieldPoint software. B. Insert the FieldPoint software CD and follow the onscreen instructions.
  • Page 12 fpoint cd.qxd 11/13/00 1:24 PM Page 11 C. In the Comm Resource Configuration dialog box, select Ethernet as the Type. D. Click Browse, select the FP-1600, and click the Device Properties button. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 13 fpoint cd.qxd 11/13/00 1:24 PM Page 12 E. In the FP-1600 Properties box, enter values for the IP address, Subnet mask, and Time server IP. You might also want to enter a comment to help you identify the FP-1600 module. •...
  • Page 14 fpoint cd.qxd 11/13/00 1:24 PM Page 13 If your modules are not listed, check the cable and connections and make sure the modules are all powered on. If you still have problems, refer to your FP-1600 user manual for troubleshooting information.
  • Page 15 fpoint cd.qxd 11/13/00 1:24 PM Page 14 Configure I/O Modules A. Right-click on the device name in FieldPoint Explorer and select Edit this Device from the pop-up menu. B. Click on the Channel Configuration button to bring up the Channel Configuration dialog box.
  • Page 16 fpoint cd.qxd 11/13/00 1:24 PM Page 15 D. Set the range and output values of the selected channel(s). E. Set the attributes for the selected channel(s) by selecting the attribute and entering the desired value. F. Send commands to the selected channel(s) by choosing a command and value and clicking on Send.
  • Page 17 fpoint cd.qxd 11/13/00 1:24 PM Page 16 Where to Go from Here After you get your hardware up and running, you might want to implement features such as power-up defaults or network watchdog settings. Refer to your FP-1600 user manual or online help for information about features, configuration, application development, and troubleshooting.
  • Page 18 fpoint cd.qxd 11/13/00 1:24 PM Page 17 FP-1600 Specifications Network interface ....10BaseT and 100BaseTX Ethernet Compatibility......IEEE 802.3 Communications rate .
  • Page 19 fpoint cd.qxd 11/13/00 1:24 PM Page 18 Mechanical Dimensions Dimensions are given in inches [millimeters]. 4.22 [107.19] 4.31 [109.5] 3.60 [91.44] Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 20 © Copyright 1999, 2000 National Instruments Corporation. All rights reserved. CVI™, FieldPoint™, LabVIEW™, Lookout™, Measurement Studio™, and ni.com™ are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...