The FieldPoint FP-3000 network module is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor.
Fieldbus-compliant output device. The control and I/O functionality of the FP-3000 can be configured by any Fieldbus configurator, such as the National Instruments NI-FBUS Configurator. This is possible because all of the features added by National Instruments are described using Device Descriptions. Any Fieldbus-compliant HMI package or OPC server can also access the FP-3000 function blocks.
DD has been installed. To install the DD for use with NI-FBUS, complete the following steps: Note This process is correct for use with National Instruments NI-FBUS. The process can vary with other host software packages. Install your Fieldbus interface and NI-FBUS software, if you have not done so already.
Updating the FP-3000 Firmware As the FP-3000 evolves, National Instruments will release updates to the module that contain new features. These new features will include support for new types of FieldPoint I/O modules as they are released, as well as new function blocks and other enhancements.
• Host configuration system capable of instantiating function blocks on devices (such as National Instruments NI-FBUS Configurator) Wire the 4–20 mA current loop into the current source input FP-AI-110 terminals. For channel zero, use terminals 1 and 17, as indicated on the wiring diagram on the front of the FP-AI-110 module.
Page 53
40° C, and the alarm is transmitted to the interface on your PC. You need a separate program (such as the Lookout HMI package from National Instruments) to receive, display, and acknowledge the alarms. You can verify that the alarms are being detected by the PID block by reading the parameter.
AI, AO, DI, and DO, to permit easy configuration and diagnostics. The FP-3000 also has National Instruments defined function blocks. All the vendor-specific blocks and enhancements are defined using Device Descriptions to interoperate with other hosts and devices.
The parameter can be disabled with the Low Cutoff option in the parameter. IO_OPTS MANUFAC_ID The ID of the manufacturer of the device. For National Instruments devices, it is 0x4E4943. MAX_NOTIFY The maximum number of unconfirmed alarm/event notification messages the device supports.
Technical Support Resources National Instruments offers technical support through electronic, fax, and telephone systems. The electronic services include our Web site, an FTP site, and a fax-on-demand system. If you have a hardware or software problem, please first try the electronic support systems. If the information...
National Instruments has branch offices all over the world. Use the following list to find the technical support number for your country. If there is no National Instruments office in your country, contact the source from which you purchased your software to obtain support.