MANUAL - SOLVENT RECYCLERS - URS1600 SERIES, URS2000 SERIES & RI 80 Rev 2019-05

PREPARATION AND SETUP:

Carefully inspect the shipping carton for any sign of transport damage.
Carefully remove the unit from the shipping carton.
Check the unit for damage. Report any transport damage immediately to the carrier and your
vendor. Initiate a freight claim with the carrier. The manufacturer is not responsible for freight dam-
age.
A Liner Bag and Retainer Ring are already installed inside the distillation tank.
Check the Accessory Kit for the parts listed below. If any parts are missing, contact your supplier. Ad-
ditional consumables and accessories are also listed.
Level the unit using the adjustable feet.

ACCESSORY KIT CONTENTS

Manual
Lid Gasket
Liner Bag, 2 Spares
Filler Hose and Suction Pipe Assembly
Note: Liner bags are not included with the model, RI80.

LOCATION AND CONNECTION:

This unit is classifi ed as Class 1, Division 1, Group D, Zone 1. Such equipment will not generate a spark.
This equipment may be safely placed in a Class 1, Division 1, Group D, Zone 1 locations where solvents
may be present. See Hazardous Location in the National Electrical Code for more information.
If this unit is placed in a Class 1, Division 2, Zone 2 or unclassifi ed location consider the area within 10
feet from the unit as Class 1, Division 2, a location where solvent is sometimes present. All equipment in
this area, such as electrical and ventilation equipment must be certifi ed for use in a Class 1, Division 2,
Zone 2 location. Such equipment cannot produce a spark. Equipment that can generate sparks, like gen-
eral plugs, welding equipment and power tools cannot be located in this area. Smoking is not permitted.
We recommend, as a best practice, that you keep this area open and free from all debris and equipment.
If you have a question contact your local fi re prevention authorities for advice. The unit must be at least 1
foot from the back wall and 10 feet from 3 other walls.
A qualifi ed electrician, in accodance with the National Electrical Code, must install an explosion
proof plug and recepticle.
Ventilation Required:
4