FEATURES AND SPECIFICATIONS

All Uni-ram Solvent Recyclers feature rapid-start direct electric heating of solvent and a short cool-
down time due to high-effi ciency condensers and air cooling with a motor driven fan.
MODEL
VOLTAGE (V) SINGLE
PHASE
BRANCH CIRCUIT
AMPS
MAX TEMPERATURE
SET POINT
TIME TO RECYCLE
TANK CAPACITY
LID GASKET
LINER BAGS
SHIPPING DIMEN-
SIONS (WDH")
WEIGHT (LB/KG)
*Note on VOLTAGE:
Operating the unit at VOLTAGE lower than 220V
(eg: 208V) may result in reduced performance.
Safety Features:
Certifi ed to UL standards U2208 and CSA standards C22.2 No. 30 and No. 88 by ETL. Approved
for use in non hazardous locations as well as approved for use in hazardous locations Class 1,
Division 1, Group D and Class 1, Division 2, Group D.
Explosion proof construction and intrinsically safe electric circuitry.
Computer controlled with many built-in safety programs including temperature control of all criti-
cal points including tank, condenser and fan motor. Power is cut when the temperature at any of
these points rises above a pre-set level. Operation also terminates when other abnormal conditions
exist (eg: boiling does not start on time or the distillation process takes too long).
Automatic pressure relief lid system prevents pressure in the Distillation Tank from exceeding 0.5
to 1.0 psi. (0.035 to 0.070 kglcm2).
Self Diagnostic error messages are displayed on the Display Panel.
Dual lid cover system.
Compact, enclosed cabinet for safe storage of the Solvent Receiving Container inside the cabinet.
URS2000SS
URS2000PW
220/240*
220/240*
30
30
200°C
240°C**
8-10 HOURS
8-10 HOURS
20 US GAL
20 US GAL
(80L)
(80L)
NEOPRENE
NEOPRENE
YES
YES
47 X 27 X 50
47 X 27 X 50
450/205
450/205
URS2000SS-TE
220/240*
220/240*
30
200°C**
8-10 HOURS
8-10 HOURS
20 US GAL
20 US GAL (80L)
TEFLON
YES
47 X 27 X 50
47 X 27 X 50
450/205
**Note on MAX TEMPERATURE SET POINT:
If a Liner Bag is used, do not use a SET POINT
greater than 205 °C.
3
RI80
URS1600SS
220/240*
30
30
240°C**
200°C
8-10 HOURS
16 US GAL
(80L)
(60L)
VITON
NEOPRENE
NO
YES
43 X 27 X 50
450/205
420/145