USER MANUAL - URS600CE AND URS600CESS
2.

Installation

2.1.

Preparation

• Carefully inspect the packaging material for traces of transport damage. Damage to the packaging
could indicate possible transport damage to the URS600CE.
• Carefully remove the URS600CE from its packaging.
• Immediately check your URS600CE for any damage.
• Report transport damage to the carrier to start the claim procedures.
• Check the accessory set you received from the list in section 1.8. If any parts are missing, please
contact the supplier where you purchased the URS600CE.
2.2.

Set-up requirements

6
WARNING
WARNING
WARNING
6
WARNING
WARNING
6
WARNING
The URS600CE should be placed in a well-ventilated and safe ATEX room without potential sources of
ignition according to the international standard EN 60079-10-1: 2009 "classification of hazardous areas
with regard to risk of explosions".
Please note that recycled solvent in the receiving container in the cabinet of the URS600CE may itself
release vapour. This will affect the zoning in your safety plan.
As far as the maximum zoning in the room where a URS600CE is placed, our advice is as follows:
The zoning that is created in the room by the URS600CE at maximum:
Zone 1:
The space inside the cabinet door where the receiving container is placed and in a radius of at
most one meter from the corners of the URS600CE.
Zone 2:
The space in a radius up to three meters from the outside corners of the URS600CE.
The URS600CE can be safely placed in zones 1 and 2 with other sources of vapours in the space.
We would like to point out that for companies working with potentially explosive atmospheres (ATEX), it is
a legal requirement to have a risk analysis and safety plan including zone classification. The final zoning
depends on the risk analysis you have carried out, the specific situation and the factors in your company.
Part of the safety plan is to acquaint the employees with the safety risks and to provide specific work
instructions. If you have any doubts about your risk analysis and/or safety plan, always consult an expert
for further advice.
If the above-mentioned set-up requirements have not been met, you may not use the URS600CE. In that
case, please contact an ATEX expert installer who can follow the installation instructions.
If the set-up requirements are not fully followed, this can result in a life-
threatening situation!
The URS600CE must be connected either to an explosion-proof ATEX
receptacle using an ATEX explosion-proof plug or by direct connection
to an explosion-proof switch that is suitable for ATEX zone 1 & 2 gas
group IIA (in accordance with the ATEX installation standard EN 60079-
14). Never connect the URS600CE yourself. Always use a competent,
certified ATEX installer.
If your workplace does not comply with the ATEX requirements then
you may not use the URS600CE. We advise you to seek advice from an
ATEX expert.
JULY 2019
15