MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 FEATURES AND SPECIFICATIONS All Uni-ram Solvent Recyclers feature rapid-start direct electric heating of solvent and a short cool- down time due to high-eff ciency condensers and air cooling with a motor driven fan. MODEL...
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 PREPARATION AND SETUP: • Carefully inspect the shipping carton for any sign of transport damage. • Carefully remove the unit from the shipping carton. • Check the unit for damage. Report any transport damage immediately to the carrier and your vendor.
Page 4
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 nection to the explosion proof plug on the cord of the recycler. The specifi cation for the plug is ... and the specifi cation for the receptacle is ... Ventilation Required: Solvents are heavier than air and accumulate near the f oor.
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 OPERATING PROCEDURES Wear protective clothing in accordance with local safety and environmental regulations. Use face goggles and gloves as a minimum. Use an apron and respirator if required. Summary of Operating Steps: 1) Open the Safety Cover and Tank Lid 2) Install the Receiving Container, the Transfer Hoses and the air Supply 3) Transfer Solvent to the Recycler Tank.
Page 6
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 2) Install the Receiving Container, the Transfer Hoses and the air Supply Receiving Container • A 20 US Gal (80 liter) container must be used to receive the distilled solvent. Make sure the Solvent Outlet Tube is properly inserted into the top opening of the Receiving Container by at least 1 inch (2.5 cm).
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 SETUP To change settings, enter Setup Mode: while pressing SETUP, press START. “SET-UP MODE” is dis- played. To change the temperature units from °C to °F, press and hold the + and - keys together for 2 seconds.
Page 8
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 5) Recycling On f rst power up and on RESET, the Display Panel shows the Software Version, then: “READY S.P. = XXX°C” (S.P. = SET POINT). When Setup is complete and START has been pressed, the “HEAT”...
Page 9
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 NOTE: If the bag sticks to the bottom of the tank, turn the recycler on for 5 minutes to loosen the bag from the bottom of the tank, then lift the bag out while the bag is warm. 9) Clean Distillation Tank and Lid Surface Distillation Tank: Wipe inside the Tank with a cloth.
Page 10
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 THEORY OF OPERATION - DISTILLATION PROCESS Waste solvent consists of the original solvent plus liquid and solid materials picked up during use of the solvent. Recycling separates the original solvent from the waste materials. During the recycling process, the distillation tank f lls with dirty solvent and the heating element heats the mixture.
Carry out each action step until a solution is found. If the recommended actions do not solve the problem call Uni-ram Service in North America or contact a qualif ed Service Technician. Caution: Disconnect the power supply before conducting maintenance or service.
Temperature Set Point. If not, pressure reduce the POWER %. Sections on Bag are brown and 1) Use of inferior low 1) Use new genuine Uni-ram high tempera- thin due to High Temperature temperature bag. ture Liner Bag and recycle. 2) The temperature 2) Run SETUP, reduce the Temperature SET-PT is too high.
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 ERROR MESSAGES If an abnormal condition is detected by the unit’s Self-diagnostic System, the Display Panel shows one of the following error messages: MESSAGE POSSIBLE CAUSE ACTION BOILING TIME OUT •...
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 SERVICE PROCEDURES 1) CLEAN CONDENSER Remove the 2 screws at the back of the Side Cover and carefully move the Side Cover forward just enough to reach the front of the condenser with a vacuum. Using a brush attachment, vacuum the front of the condenser where most of the dust accumulates and then vacuum the back if necessary.
Page 15
MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE Revised 2017-10 4) INCREASE LID TENSION (BY ADJUSTING THE SPRING BOLT) CAUTION: SHOULD BE DONE ONLY AS A LAST RESORT - FIRST CHECK FOR A WORN LID GASKET, A BLOCK- AGE IN THE SOLVENT FLOW PATH , LOOSE HINGE BOLTS OR A SET POINT THAT IS TOO HIGH FOR THE SOLVENT BEING RECYCLED.
960-8240 TIMER ASSEMBLY WITH KNOB 115-20015 CAUTION USE ONLY GENUINE UNI-RAM LINER BAGS WHICH ARE 3 MIL THICK, LIGHT BLUE IN COLOUR. THEY ARE SPECIALLY MANUFACTURED TO BE STRONG, HEAT RESISTANT AND CHEMICAL RESISTANT. USE OF A NON-UNI-RAM LINER BAG MAY VOID THE WARRANTY.
Page 18
“Conditions of Warranty” as consumables are not covered. Uni-ram reserves the right to direct the customer to ship the unit collect to the Uni-ram factory or to an ap- proved Service Center for repair using the Uni-ram Return Goods Procedure or to repair the unit on-site.