2.7.1 Connecting Ac Power - Siemens SIMATIC NET RUGGEDCOM MX5000 Installation Manual

Hide thumbs Also See for SIMATIC NET RUGGEDCOM MX5000:
Table of Contents

Advertisement

Installing the Device
2.7.1 Connecting AC Power
2.7.1
Connecting AC Power
To connect AC power to the device, do the following:
Electrocution hazard – risk of death, serious personal injury and/or damage to
the device
Make sure the supplied cover is always installed over high voltage screw-type
terminal blocks.
Electrical hazard – risk of damage to equipment
Do not connect AC power cables to a DC power supply terminal block. Damage to
the power supply may occur.
Note
The terminal block is installed using Philips screws and compression plates, allowing
either bare wire connections or crimped terminal lugs. Use #6 size ring lugs for
secure, reliable screws, which must be removed to make connections.
16
For 125/230 VAC rated equipment, an appropriately rated AC circuit breaker
must be installed.
For 125/250 VDC rated equipment, an appropriately rated DC circuit breaker
must be installed.
It is recommended to provide a separate circuit breaker for each power module
module.
Equipment must be installed according to applicable local wiring codes and
standards.
DANGER
NOTICE
RUGGEDCOM MX5000
Installation Manual, 01/2021, C79000-G8976-1059-13