Cables - Husqvarna K4000 Workshop Manual

Hide thumbs Also See for K4000:
Table of Contents

Advertisement

nozzle has a smaller diameter compared to the gasoline
cutters in order to limit the quantity of water.
1. To remove the spray nozzle, the belt guards must
first be removed. See
Break on page 41

6.13 Cables

6.13.1 To remove cables from the terminal bar
The terminal bar is used to connect the ground wires. It
must not be used again if cables have been removed
from it. The terminal bar has a sealing gel which
prevents moisture get through to the contact surfaces.
1. Break up the contact strip with a screwdriver.
2. Pull out all cables. The cables must be cut by
approx. 5 mm in order to make new contact surfaces
for the contact strip
46 - Repair and servicing
To remove the belt Cut-n-
6.13.2 To put cables into the terminal bar
1. Put the cables all the way to the bottom of the
terminal bar. Note that the cables must not be
stripped.
2. Push together the splice sleeve using a pair of
pliers. Pull the cables to make sure they are locked
against the splice sleeve.
6.13.3 To remove splices
Moisture proof splice sleeves are installed on the cables
from the circuit board to the stator. It is necessary to cut
the splice points if you must change the stator or circuit
board.
1. Cut the cable by approx. 7 mm from the outer ends
of the splice sleeve.
2. Strip the two parts of the sleeve and cable at the
same time.
X
X
474 - 002 - 27.06.2018

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents