1. Account Active -​ ​ Y es
2. Primary SIP Server ​ - ​ T he IP address of your Ignition gateway ​ ( Note: since the box
will not actually register with Ignition, in a redundant setup it should be sufficient to
simply enter the master address)
3. SIP User ID, Authenticate ID, Name -​ ​ A ny simple name/id
4. SIP Registration -​ ​ No
5. Outgoing Call without Registration ​ - ​ Y es
6. Local SIP port -​ ​ 5060
7. DTMF Payload Type ​ - ​ 1 01
8. Preferred DTMF method, Priority 1 -​ ​ RFC2833
9. Number of Rings (FXO Termination) ​ - ​ 1
10. PSTN Ring Thru FXS ​ - ​ N o
11. PSTN Ring Thru Delay ​ - ​ 1
12. Wait for Dial​ T one (Channel Dialing) ​ - ​ N o
13. Stage Method ​ - ​ 1
SIP Register Contact Header uses - ​ D efault is LAN ​ b ut it needs to correspond to the
interface Ignition is plugged into (LAN/WAN).
Note:​ It has been observed that in some environments, the Current Disconnect Threshold (ms)
setting must be set higher in order for calls to be made successfully. If everything appears to be
fine but calls are not placed, try increasing the value to 800:
5) Configure Ignition
1. Create a new voice notification profile by going to Gateway
Configuration>Alarming>Notification>Create new profile, and selecting "VOIP"
2. Enter the IP address assigned to the box
3. ​ L eave the username and password blank