Characteristics
• Used for remote control of the luminaire: ON / OFF / DIMM.
• Module measures current fl ow - fault detection (ballast fault, light source, con-
necting wires ...).
• The two-directional communication module is intended primarily for monitoring
and switching of public lighting in cities,
• Using a monitoring and switching component will help you eliminate fi nancial
costs.
• Communicates over the wireless LPWAN network (LoRa).
• Data is sent to the server from which it can be subsequently displayed as a smart-
phone, application, or Cloud notifi cation.
• Update using the RFAF / USB Service Key.
Description
1
2
3
4
5
Cloud app assignment
It is done in your Smartphone application. Enter the relevant information on the product
cover into the application.
Function
When power is applied, the module sends a start message.
It monitors the current flow and sends a data message according to the settings in the
application (within 5 min - 24 hrs). In case of a significant change in measurement, it
sends the data message immediately.
Controls lighting based on application command.
• The TEST button is for service purposes.
Long press of the TEST button - adjust the brightness (ascending or descending ramp).
Briefly press the TEST button to turn on / off the connected device.
6
1. Hole for mounting on the wall Ø
4.3 mm / 0.2"
1
2. Cable
3. N - Light blue (neutral conductor)
7
4. L - brown (phase)
5. V - black (switch output)
8
6. Antenna (length 76mm, Ø 8 mm)
7. Button TEST
8. LED
- green LED - illuminates when
power is applied
- orange LED - lights up when the
output is turned on
9. Cable gommet M16x1.5 for cable
9
max. Ø 10 mm / 0.4"
10. (-) - dark blue DALI
11. (+) - red DALI
10
11
AirSLC-100/DALI
Street light controller (DALI)
General instrucions
Internet of Things (IoT)
• The IOT wireless communications category describes the Low Power Wide Area
(LPWA). This technology is designed to provide full-range coverage both inside and
outside buildings, energy-saving and low-cost operation of individual devices. Indi-
vidual networks - LoRa - are available to use this standard.
LoRa network information
• The network is bidirectional and its communication uses free frequency band.
865 - 867 MHz
867 - 869 MHz
902 - 928 MHz
• The advantage of this network is the possibility of freely deploying individual stations
in local locations, thus strengthening their signal. It can therefore be used effi ciently in
company premises or, for example, in local parts of cities.
• For more information on this technology, please visit www.lora-alliance.org.
Caution for proper operation:
• Products are installed according to the wiring diagram given for each product.
• For proper device functionality, it is necessary to have suffi cient coverage of the se-
lected network at the installation site.
• At the same time, the device must be registered in the network. Successful device reg-
istration on a given network requires a charge for traffi c.
• Each network off ers diff erent tariff options - it always depends on the number of mes-
sages you want to send from your device. Information on these tariff s can be found in
the current version of the ELKO EP pricelist.
Example connection
brown
L
light blue
N
DALI(+)
DALI(-)
For the management of DALI BUS there is not an exact cable type recommended, but
it is important to keep some installation conditions. For DALI BUS lines up to 100 m
the recommended min. conductor cross section is 0.5 mm
100 m -150 m a cross section of 0.75 mm
1.5 mm
2
. Management of more than 300 m is not recommended. The voltage drop at the
end of the installation may not be greater than 2 V.
1 / 2
India
Europe
North America, Japan, Korea
black (V)
DALI
L
N
red
DALI (+)
dark blue
DALI (-)
ballast
2
. For management between
2
and more than 150 m the recommended min is
EN
light source

Advertisement

loading

Summary of Contents for Elko iNELS Air AirSLC-100

  • Page 1 3. N - Light blue (neutral conductor) sages you want to send from your device. Information on these tariff s can be found in the current version of the ELKO EP pricelist. 4. L - brown (phase) 5. V - black (switch output) 6.
  • Page 2 Technical parameters Assembly AirSLC-100L/DALI Supply voltage: 110 - 230 V AC / 50 - 60 Hz Apparent input: 3 VA Click! Dissipated power: 1.2 W Supply voltage tolerance: +10 /-15 % Output Communication Interface: active (self-powered) polarized, the ability to connect one device Output voltage: 20 mA 1.

This manual is also suitable for:

Inels air airslc-dali