Event Reporting

When using contact ID and SIA formats all event codes are programmed into the X64 and only need to be
enabled or disabled in the following locations. Also the split reporting group can be allocated.
These locations are for each of the zones, 501 is for zone 1, 502 is for zone 2, 503 is for zone 3, etc.
LED
ON/OFF
Action
1
ON
Zone alarm reporting
2
OFF
Zone alarm restore
3
OFF
Zone bypassing
4
OFF
Zone force bypassing
5
OFF
Zone tamper
6
OFF
Zone tamper restore
Zone swinger
7
OFF
shutdown
Zone swinger
8
OFF
shutdown restore
Options 9 to 16 are to select which split reporting telephone numbers to report too.
Off = split reporting group 1, On = split reporting group 2
LED
On/Off
Action
1
ON
AC fail reporting
Communication fail
2
OFF
reporting
Telephone line tamper
3
ON
reporting
4
ON
Siren fail reporting
Panel low battery fail
5
ON
reporting
Enable aux 12V fuse fail
6
ON
reporting
7
OFF
Installer Reset Required
8
ON
Box tamper reporting
Options 9 to 16 are to select which split reporting telephone numbers to report too.
Off = split reporting group 1, On = split reporting group 2

Location 501 to 564 Global Split Reporting

Explanation
If this option is selected whenever a zone is violated
the alarm reports via telephone
When the zone restores the alarm reports via
telephone
When a zone is bypassed it is reported via telephone
When the system is set to bypass zones that are
violated when arming it reports that it was forced to
arm by bypassing zones
When tamper has been set for a zone and the
tamper signal is received it will be reported via
telephone
When the tamper restores a report is sent via
telephone
A zone shuts down because it has exceeded the
shutdown count and the system will report via
telephone
At the auto test report, the system will try and restore
the zone if it is not violated and this will be reported
via telephone

Location 571 Global Split Reporting

Explanation
After the wait time set in loc.?? The AC failure will be
reported
If the system cannot report a failure to report message
is sent
The alarm monitors the voltage on the telephone line
and if that it goes missing a tamper is reported
The siren output monitors the load on the output and if
it goes missing then a tamper is reported
When AC is off and the battery voltage drops to 10.5V
a battery low signal is sent, warning that the system is
close to shutting down
If a short circuit or too much current is drawn from the
auxiliary 12V the fuse will shut off and send a signal
warning of a problem
If installer reset is enabled in loc.211 to 218 and the
alarm is triggered the system will not arm until the
installer code is entered. This alerts the security
company of this
The alarm has an input that monitors a switch that
monitors if the housing that it is in is opened
Split Reporting
Option
9 OFF
10 OFF
11 OFF
12 OFF
13 OFF
14 OFF
15 OFF
16 OFF
Split Reporting
Option
9 OFF
10 OFF
11 OFF
12 OFF
13 OFF
14 OFF
15 ON
16 OFF
IDS | Event Reporting
15