(217) 352-9330 | Click HERE Find the Acromag IP400 at our website:...
Page 2
40-Channel Digital Input Board USER’S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road P.O. BOX 437 Wixom, MI 48393-7037 U.S.A. Tel: (248) 624-1541 Fax: (248) 624-9234 Copyright 1995, Acromag, Inc., Printed in the USA. Data and specifications are subject to change without notice. 8500-532-D01E003...
The information contained in this manual is subject to change IMPORTANT SAFETY CONSIDERATIONS without notice. Acromag, Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied It is very important for the user to consider the possible adverse warranties of merchantability and fitness for a particular purpose.
BOARD CONFIGURATION except for shorter printed circuit board depth. It connects to Acromag Termination Panel 5025-552 from the rear of the card Power should be removed from the board when installing IP cage, and to AVME9630/9660 boards within the card cage, via modules, cables, termination panels, and field wiring.
The IP400 P2 connector shares the same the P1 connector and these are indicated in BOLD ITALICS. signal pinouts with Acromag Model IP405 40-Channel Output Boards, making it directly compatible for “loopback” monitoring of the Table 2.2: Standard Logic Interface Connections (P1) IP405 output states.
Used” addresses occur due to the IP400’s use of the same level specified by the Interrupt Polarity Register occurs (i.e. Low or register architecture as Acromag Model IP408. High level transition interrupt). A “1” bit means the interrupt will 4. All Read and Write operations require 1 wait state.
After the highest numbered channel’s interrupt is serviced and cleared, an additional interrupt will be generated for the next highest priority channel with an interrupt pending. Note that the Acromag ID Code input channel bandwidth should be limited to reduce the possibility of IP Model Code missing channel interrupts.
To make programming and communicating with the board 2. Perform Specific IP Module Programming - see the Change-of- easier, Acromag provides you with the Industrial I/O Pack Software State or Level Match programming examples that follow, as Library diskette. The functions provided are written in the “C”...
It is highly recommended that a non-functioning This section describes the basic functionality of the circuitry board be returned to Acromag for repair. The board can be easily used on the board. Refer to the Block Diagram shown in Drawing damaged unless special SMT repair and service tools are used.
SAMA PMC 33.1 test REMOVING OR INSERTING BOARDS procedures. Resistance to EMI......Unit has been tested with no Acromag’s Applications Engineers can provide further technical digital upsets under the influence assistance if required. When needed, complete repair services are of EMI from switching solenoids, also available from Acromag.
Cable: 50-wire flat ribbon cable, 28 gage. Non-Shielded cable the mating area (per MIL-G-45204, Type II, Grade C). model uses Acromag Part 2002-211 (3M Type C3365/50 or Connects to Acromag termination panel 5025-552 from the rear equivalent). Shielded cable model uses Acromag Part 2002-261 of the card cage via flat 50-pin ribbon cable (cable Model (3M Type 3476/50 or equivalent).