KTR RADEX-NC Operating & Assembly Instructions

KTR RADEX-NC Operating & Assembly Instructions

Backlash-free, torsionally stiff and maintenance-free steel laminae couplings

Advertisement

Quick Links

KTR Kupplungstechnik
GmbH
D-48407 Rheine
RADEX
Backlash-free, torsionally stiff and
maintenance-free steel laminae
couplings
type DK and EK
and their combinations
according to Standard 94/9/EC
(ATEX 95) for finish bored, pilot
bored and unbored couplings
Gezeichnet:
Schutzvermerk
ISO 16016 beachten.
Geprüft:
Operating-/Assembly instructions
®
-NC
23.05.12Kb
23.05.12 Kb
®
RADEX
-NC
Ersatz für:
Ersetzt durch:
KTR-N
47210 EN
sheet:
1 of18
edition:
6
Type DK
Type EK
KTR-N vom 26.03.09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RADEX-NC and is the answer not in the manual?

Questions and answers

Summary of Contents for KTR RADEX-NC

  • Page 1 DK and EK and their combinations according to Standard 94/9/EC (ATEX 95) for finish bored, pilot bored and unbored couplings Type EK Gezeichnet: 23.05.12Kb Ersatz für: KTR-N vom 26.03.09 Schutzvermerk ISO 16016 beachten. Geprüft: 23.05.12 Kb Ersetzt durch:...
  • Page 2: Table Of Contents

    Marking of coupling for the hazardous area 5.6 Starting 5.7 Breakdowns, causes and elimination 5.8 EC Certificate of Conformity according to the EC Standards 94/9/EC dated 23 March 1994 Gezeichnet: 23.05.12Kb Ersatz für: KTR-N vom 26.03.09 Schutzvermerk ISO 16016 beachten. Geprüft: 23.05.12 Kb Ersetzt durch:...
  • Page 3 (e. g. combinations with brake drums, brake disks, overload systems like torque limiters, impellers etc.) are not allowed for the use in hazardous areas. A separate checking must be made. Gezeichnet: 23.05.12Kb Ersatz für: KTR-N vom 26.03.09 Schutzvermerk ISO 16016 beachten. Geprüft: 23.05.12 Kb Ersetzt durch:...
  • Page 4: Technical Data

    Typical drives with endangered torsional vibration are e. g. drives with diesel engines, piston pumps, piston compressors etc. On request KTR makes the coupling selection and the torsional vibration calculation.
  • Page 5: General Hints

    When using the coupling in hazardous areas please observe the special hints and instructions regarding safety in enclosure A. The mounting instructions are part of your product. Please keep them carefully and close to the coupling. The copyright for these mounting instructions remains with KTR Kupplungstechnik GmbH. 2.3 Safety and Advice Hints STOP D A N G E R ! Danger of injury to persons.
  • Page 6: Storage

    Quantity Designation Clamping hub Cap screws DIN EN ISO 4762 Laminae package Cap screws DIN EN ISO 4762 ® illustration4: RADEX -NC type EK Gezeichnet: 23.05.12Kb Ersatz für: KTR-N vom 26.03.09 Schutzvermerk ISO 16016 beachten. Geprüft: 23.05.12 Kb Ersetzt durch:...
  • Page 7: Hint Regarding The Finish Bore

    Any mechanical rework to couplings that are used in hazardous areas require an explicit release by KTR. The orderer must send a drawing to KTR acc. to which the manufacture must be made. KTR checks this drawing and returns it to the orderer with approval.
  • Page 8 Z 390312 Z 391674 Z 391668 Z 391671 Z 391670 Z 391675 Z 390408 Z 391672 Z 388611 Z 388610 Z 391669 Z 391673 Gezeichnet: 23.05.12Kb Ersatz für: KTR-N vom 26.03.09 Schutzvermerk ISO 16016 beachten. Geprüft: 23.05.12 Kb Ersetzt durch:...
  • Page 9 • Please control with a dial gauge, ruler or feeler whether the permissible displacement values of table 6 are adhered to. Radial displacements Axial displacements Angular displacements illustration 8: displacements Gezeichnet: 23.05.12Kb Ersatz für: KTR-N vom 26.03.09 Schutzvermerk ISO 16016 beachten. Geprüft: 23.05.12 Kb Ersetzt durch:...
  • Page 10 A basic requirement to guarantee the operational readiness of the coupling is a stock of the most important spare parts on site. Contact addresses of the KTR partners for spare parts and orders can be obtained from the KTR homepage under www.ktr.com.
  • Page 11 Device class I of category M2 (coupling is not approved for device category M1). Permissible ambient temperature - 30 °C to + 140 °C. Gezeichnet: 23.05.12Kb Ersatz für: KTR-N vom 26.03.09 Schutzvermerk ISO 16016 beachten. Geprüft: 23.05.12 Kb Ersetzt durch:...
  • Page 12 „Breakdowns“, as far as possible. The maintenance intervals must be adjusted according to the changed operating parameters. ® illustration 10: RADEX Gezeichnet: 23.05.12Kb Ersatz für: KTR-N vom 26.03.09 Schutzvermerk ISO 16016 beachten. Geprüft: 23.05.12 Kb Ersetzt durch:...
  • Page 13 Semifinished products from aluminium with a magnesium part of up to 7,5 % and a yield point of ≥ 250 N/mm are permitted for the use in hazardous areas. p0,2 Aluminium diecast is generally excluded for hazardous areas. Gezeichnet: 23.05.12Kb Ersatz für: KTR-N vom 26.03.09 Schutzvermerk ISO 16016 beachten. Geprüft: 23.05.12 Kb Ersetzt durch:...
  • Page 14 Any mechanical rework to couplings that are used in hazardous areas require an explicit release by KTR. The orderer must send a drawing to KTR acc. to which the manufacture must be made. KTR checks this drawing and returns it to the orderer with approval.
  • Page 15 • Tightening torques are below/exceeded. • Components are exchanged by mistake/put together incorrectly. • A wrong or no laminae package is inserted into the coupling. Gezeichnet: 23.05.12Kb Ersatz für: KTR-N vom 26.03.09 Schutzvermerk ISO 16016 beachten. Geprüft: 23.05.12 Kb Ersetzt durch:...
  • Page 16 5.8 Breakdowns, Causes and Elimination Continuation: • No original KTR parts (purchased parts) are used. • The coupling used/the coupling protection used is not suitable for the operation in hazardous areas and does not correspond to EC Standard 94/9/EC, respectively.
  • Page 17 A T T E N T I O N ! KTR does not assume any liabilities or guarantees regarding the use of spare parts and accessories which are not provided by KTR and for the damages resulting herefrom.
  • Page 18 94/9/EC. One or several standards mentioned in the corresponding EC type test certificate IBExU05ATEXB002 X were in part replaced by updated versions. KTR Kupplungstechnik GmbH as the manufacturer confirms that the product mentioned above is in accordance with the specifications of the new standards,too.