TECHNICAL CHARACTERISTICS according to EN 13229 The given data are indicative and taken
during the certification stage at a notified Body under regulation conditions.
The results were obtained with the glass cleaning system closed, by the installer.
Power output
Efficiency
Emissions CO 13% O
Fumes temperature
Minimum draught
Fuel consumption *
Heatable volume **
Smoke outlet pipe diameter
Weight including packaging
Energy efficiency class accor-
ding to UE 2015- 1186 regula-
tion (Class A++/G)
6
*A calorific value of 4.8 kW/Kg has been used to calculate consumption
** The heating volume is calculated with the heat request of 33 Kcal/m³ hour
TECHNICAL DATA FOR THE DIMENSIONING OF THE FLUE
Temperature of fumes on exit from
the discharge pipe
Minimum draught
Fume flow capacity
Intermittent mode combustion device
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
GENERAL INFORMATION
WINDO 70
14,3
81,4
0,07
2
252
11
3,8
375
220
A+
WINDO 70
302
10
12
WINDO 90
WINDO 100
Nominal power
17,6
18
81,1
78,2
0,09
0,07
238
261
12
11
4,7
5
460
470
180
250
380
A+
A
WINDO 90
WINDO 100
Nominal power
285
313
10
10
13
17,7
WINDO 120
19,2
kW
78,2
%
0,06
%
216
°C
11
Pa
5,3
kg/h
500
m
3
mm
430
kg
A
WINDO 120
313
°C
10
Pa
18,9
g/s