Image Industries QuikLinx SW750 Operation Manual page 20

Drawn arc stud welding power source single output
Table of Contents

Advertisement

Section 3
ADVANCED FEATURES CONTINUED
HAMMER MODE CONTINUED
To enable and adjust the hammer mode you must enter the welder's parameter adjustment mode.
NOTE: Hammer Mode does NOT apply/work with the QuikLinx tool.
Parameter Adjustment Mode
To enter parameter adjustment mode the user needs to enter the following key sequence within 5 seconds:
Current UP
Time DOWN
Current DOWN
Time UP
The upper display will now show:
The lower display will show:
The Top UP/DOWN Buttons (Current) Changes the Parameter P1 to P2 and so on.
The lower UP/DOWN Buttons (Time) Adjust the parameter value, for example, off to on
Parameters Table
Use the Current buttons to select the parameter you are interested in adjusting. Example P1
Use the time buttons to change the value of the parameter. Example from off to on
You may adjust all parameters this way.
When you have finished adjusting parameters, press the gas button. This will enter the SAVE mode.
Use the time buttons to change from no to Yes.
Press the gas button again to write the new parameters to memory.
If you press the gas button with no as the Save parameter the unit will exit the parameter adjustment mode and no changes
will have been saved.
Lift Check
If the hammer mode is off and the system does not detect ground (i.e. the weld tool is air triggered), the weld tool will cycle
once without welding. This is useful for checking lift settings in the weld tool. If gas flow is enabled, gas will flow during lift
check. This can be used on power up to purge the gas line.
NOTE: Gas does NOT flow during a lift check with the QuikLinx tool.
P1
off
Parameter
P1
P2
DEF
LoC
Locks the front panel from changing; on/off
Normal Operation
Meaning
Hammer Mode on/off
Number of Hammers 1-10
Restore Default Parameters; yes/no
19