Image Industries QuikLinx SW750 Operation Manual page 12

Drawn arc stud welding power source single output
Table of Contents

Advertisement

Section 2
RECOMMENDED WIRING SEQUENCE
Set the power source jumper links to match
1.
incoming voltage.
Connect the incoming power leads to the welding
2.
power source.
Connect the incoming cable to the disconnect box.
3.
Connect the weld ground and cables.
4.
SETTING JUMPER LINKS
There are several jumper links that must be set before
connecting electrical power to the welder for both the
main transformer and control transformer. Always verify
jumper settings before connecting electrical power to
any device. Use 7/16 socket wrench or nut driver to
ensure the jumper link nuts are tight.
JUMPER LINK LOCATION
Use a straight blade screwdriver to turn the access panel
latch to the vertical position. The door will be able to
be opened. When finished, close the access panel door
and using a screw driver turn the latch to the horizontal position to lock the door closed.
2 Separate Jumper Links for 230V
3 Places A, B, C
1 Jumper Link for 230V
1 Place D (Top Position)
Installation & Set Up
Jumper Panel
Access Door
Rear of the
Power Source
A
B
D