Drawn arc stud welding power source single output
Table of Contents

Advertisement

Section 2
Connecting Incoming Power
DANGER
screwdriver to turn the access panel latch to the vertical position. The
door will be able to be opened. When finished close the access panel
door and using a screw driver turn the latch to the horizontal position
to lock the door in a closed position.
L1
L2 L3
Your L1, L2 & L3 colors may vary.
L1, L2 & L3 order (rotation) does not matter
To connect incoming electrical power
it is necessary to open the electrical
access panel on the rear of the power
source. Use a straight blade
Ground
Recommended
Voltage
Fusing (Delay Type)
230
60 Amp
460
30 Amp
575
20 Amp
Installation & Set Up
Jumper Panel
Access Door
Rear of the
Power Source
Strip back the outer cable jacketing so there is
approximately 5" (125mm) of insulated leads. Strip
approximately ½" (12mm) of insulation on each
conductor. Thread the 4 leads through the cord grip
on the lower center back of the back of the welder.
Connect the ground lead to the identified ground lug
first.
Use the provided lugs to secure this lead. Connect
the incoming wires to L1, L2 and L3 as shown in the
picture on the left. Use a large flat bladed
screwdriver to secure the incoming leads to the lugs.
These connections should be tight. Tighten cord grip
onto incoming cable jacket.
When complete, close the rear access door, turn the
latch to secure and connect the incoming power
cable to the disconnect box or outlet.
Minimum Copper Line
& Ground Wire Size
90°C THHN Copper
6 gauge
10 gauge
12 gauge