Sound Pressure Levels - Nibe F2040-6 Installer Manual

Air/water heat pump
Hide thumbs Also See for F2040-6:
Table of Contents

Advertisement

Sound pressure levels

F2040 is usually placed next to a house wall, which gives
a directed sound distribution that should be considered.
Accordingly, you should always attempt when position-
ing to choose the side that faces the least sound sens-
Air/water heat pump
Sound power level* According to EN12102 at 7/45 (nominal)
Sound pressure level at 2 m free standing.*
Sound pressure level at 6 m free standing.*
Sound pressure level at 10 m free standing.*
* Free space.
64
Chapter 12 | Technical data
itive neighbouring area.
The sound pressure levels are further affected by walls,
bricks, differences in ground level, etc and should
therefore only be seen as guide values.
F2040 adjusts the fan speed depending on the ambient
temperature and evaporation temperature.
2 m
2 m
6 m
10 m
F2040-6
L
(A)
50
W
dB(A)
36
dB(A)
26.5
dB(A)
22
F2040-8
F2040-12
F2040-16
54
57
40
43
30.5
33.5
37.5
26
29
NIBE F2040
61
47
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F2040-8F2040-12F2040-16