  • Page 1 Installer manual NIBE™ F2030 Air/water heat pump IHB GB 1540-4 231115...
  • Page 3: Table Of Contents

    11 Technical data 6 Commissioning and adjusting Dimensions and setting-out coordinates Sound pressure levels Preparations Technical specifications Filling and venting the heating medium sys- Energy labelling Balance temperature Electrical circuit diagram Stop temperature Index Soft-starter NIBE™ F2030 Table of Contents |...
  • Page 4: Important Information Safety Information

    1 Important information Marking Safety information The CE marking means that NIBE ensures that the This manual describes installation and service proced- product meets all regulations that are placed on it ures for implementation by specialists. based on relevant EU directives. The CE mark is obligat-...
  • Page 5 Do not install the outdoor unit in a location where insects Use main switch with sufficient breaking capacity. and small animals can inhabit. NIBE™ F2030 Chapter 1 | Important information...
  • Page 6 Country specific information the system worse. - When filling refrigerant, the refrigerant must always leave the Installer manual bottle in liquid form. This installer manual must be left with the customer. Chapter 1 | Important information NIBE™ F2030...
  • Page 7 Charge flow set Fuses property Safety breaker Earth circuit-breaker Heating cable type/effect Fuse size, heating cable (F3) Communication cable connected Miscellaneous Condensation water pipe Insulation condensation water pipe, thickness (if KVR 10 is not used) NIBE™ F2030 Chapter 1 | Important information...
  • Page 8 NIBE Energy Systems France Sarl, Zone industrielle RD 28, Rue du Pou du Ciel, 01600 Reyrieux Tel : 04 74 00 92 92 Fax : 04 74 00 42 00 E-mail: info@nibe.fr www.nibe.fr NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: info@nibe.co.uk www.nibe.co.uk...
  • Page 9: Delivery And Handling

    8). Care must be exercised so that the heat pump is not ■ scratched during installation. min 300 mm Do not place F2030 directly on the lawn or other non solid surface. NIBE™ F2030 Chapter 2 | Delivery and handling...
  • Page 10 When the F2030 is lifted by crane the packaging must be untouched and The condensation water (up to 50 litres/day) collec- ■...
  • Page 11 LEK/ frost free depth. If the house has a cellar the stone caisson must be po- Route the pipe downward from F2030. sitioned so that condensation water does not affect The condensation water pipe must have a water seal the house. Otherwise the stone caisson can be posi- to prevent air circulation in the pipe.
  • Page 12: Supplied Components

    Installation area The distance between F2030 and the house wall must be at least 350 mm. Clearance above the F2030 should be at least one metre. Free space behind 350 mm Fritt utrymme bakom 600 mm 400 mm 600 mm...
  • Page 13: Removing The Side Cover

    Removing the side cover NIBE™ F2030 Chapter 2 | Delivery and handling...
  • Page 14: The Heat Pump Design General

    3 The heat pump design General EB13 AA100 BT17 EB11 XL21 AA101 XL40 QN31 QN30 QN34 BT15 GQ10 BT14 BP10 XL20 EB10 BT28 BT12 BT16 XL40 Chapter 3 | The heat pump design NIBE™ F2030...
  • Page 15 Pipe connections Connection, heating medium out of F2030 Connection, heating medium in to F2030, XL20 Service connection, high pressure XL21 Service connection, low pressure XL40 Connection, drain condensation water trough Sensors etc. High pressure pressostat Low pressure pressostat BP10 High pressure pressostat...
  • Page 16: Electrical Panel

    Terminal block, incoming supply Terminal block, charge pump, external heater Terminal block, common alarm Terminal block, thermostat, compressor blocking and communication indoor module. Designations in component locations according to standard IEC 81346-1 and 81346-2. Chapter 3 | The heat pump design NIBE™ F2030...
  • Page 17: Pipe Connections

    Pressure drop, heating medi- um side Pipe installation must be carried out in accordance with current norms and directives. F2030 can only operate up to a return temperature of F2030 -7, 9 about 55 °C and an outgoing temperature of about F2030 Tryckfall(värmebärarsida) 65 °C from the heat pump.
  • Page 18: Electrical Connections

    ■ ate supply or to terminal block (X3). motor characteristic "C" (compressor operation). For NOTE! If F2030 is not powered and the charge pump MCB size see "Technical Specifications". is connected to the terminal block (X3) there is a risk F2030 does not include an omnipolar circuit breaker ■...
  • Page 19 Accessibility, electrical connection Removing the side cover Unscrew the screws and lift off the cover. NIBE™ F2030 Chapter 5 | Electrical connections...
  • Page 20: Connections

    Incoming supply cable is supplied and factory connec- ted to the terminal block -X1. Approx. 1.8 m cable is accessible outside the heat pump. On installation the unions must be mounted on the rear of the heat pump. Chapter 5 | Electrical connections NIBE™ F2030...
  • Page 21 Connecting external control voltage Charge pump To let F2030 control the charge pump (GP12), connect NOTE it to the terminal block X3:1(PE), 3(L) and 4(N). Pump Mark up any junction boxes with warnings for activity is dependent on the status of F2030, heat- external voltage.
  • Page 22 External heating cable (KVR 10) Cable routing The following image displays the recommended cable F2030 is equipped with a plinth for external heating routing from the junction box to the condensation cable EB14, not supplied). The connection is fused with water trough on the outside of F2030.
  • Page 23: Optional Connections

    Downtime AA21-J6 Stillestånd do not apply when F2030 is controlled by a NIBE indoor module. Max load across the relay contactors is 250V 2A. Thermostat control During operations without the need of the additional...
  • Page 24: Connecting Accessories

    For connection of indoor module, see relevant manual on www.nibe.eu. External indication of main alarm F2030 is equipped with a contact for external indication of common alarms. The function becomes active with all types of existing alarms. Max load on the relay con- tact is250V 2A.
  • Page 25: Commissioning And Adjusting Preparations

    1. The heating medium system is filled with water to the required pressure. F2030 is equipped with a collar heater that can heat 2. Vent the system using the venting nipple on the the fan collar if necessary (not activated upon delivery).
  • Page 26: Start-Up And Inspection

    10. Once the connection is made, the compressor starts 2. Turn the isolator switch on. after approx. 180 minutes if needed. 3. Ensure that the F2030 is connected to the power 11. Adjust the charge flow according to the diagram, source.
  • Page 27: Adjustment, Charge Flow

    30 % to obtain a For the heat pump to function correctly all year, the lower T. charge flow must be adjusted using the NIBE indoor module or according to the procedure below, with The diagrams show the heat pump with a high fan other controls.
  • Page 28: Control - Introduction

    F2030 communicates with NIBE SMO or the indoor Minus button module which means that settings and measurement values from F2030 can be adjusted and read off in the The minus button (S2) is used to browse indoor module. through the channel system (backwards) or lower the value of the selected parameter.
  • Page 29: Display Explanation

    Shows the current channel. Change channels using the Plus button or the Minus button. Fan on, low speed Value: 01 Fan on, high speed Shows the current value. Increase/decrease value using the plus button respective minus button. NIBE™ F2030 Chapter 7 | Control - Introduction...
  • Page 30: Control Conditions

    B = Set temperature for cold outdoor air (channel A7). A = Set temperature for cold outdoor air + 2.1 °C. Outdoor temperature Utelufttemperatur utelufttemp. Chapter 7 | Control - Introduction NIBE™ F2030...
  • Page 31 (if the pressure has fallen), not correct and therefore displays too low temper- otherwise there is a constant high pressure alarm ature (at cold outdoor air). (alarm 06). NIBE™ F2030 Chapter 7 | Control - Introduction...
  • Page 32 5. The temperature on the flow temperature sensor falls below 4 °C. Chapter 7 | Control - Introduction NIBE™ F2030...
  • Page 33: Control - Channels

    Status S7 1 / 1 / 1 These channels show the status and statistics. Displays time until next defrost. Software version number. Channel Shows the operating status of F2030. Value Temperature channels Normal operation. Defrosting is run. Temp. Cold outdoor air temperature.
  • Page 34: Setting Channels

    0 stands for only active, with the indoor module. time controlled defrosting. Factory setting 1. For example 3 x F2030 in the same system are alloc- ated the addresses 1, 2 and 3. NOTE In the event of a defrosting problem the Connection difference return temperature.
  • Page 35: Disturbances In Comfort Troubleshooting

    ■ NOTE Fuses have tripped. ■ As F2030 can be connected to a large number Replace the fuse or reset the MCB. ■ of external units, these should also be checked. Cold outdoor air. Indicated as 03 in channel S1.
  • Page 36 Temperature sensor, heating medium return line BT12 Temperature sensor, condenser supply line BT14 Temperature sensor, hot gas BT15 Temperature sensor, fluid pipe BT16 Temperature sensor, evaporator BT17 Temperature sensor, suction gas BT28 Ambient temperature sensor Chapter 9 | Disturbances in comfort NIBE™ F2030...
  • Page 37 5.306 1.752 5.37 2.67 4.348 1.587 4.69 2.50 3.583 1.426 4.10 2.33 2.968 1.278 2.467 1.136 2.068 1.007 1.739 0.891 1.469 0.785 1.246 0.691 1.061 0.607 0.908 0.533 0.779 0.469 0.672 0.414 NIBE™ F2030 Chapter 9 | Disturbances in comfort...
  • Page 38 2.186 1.59 1.817 1.39 1.518 1.22 1.274 1.07 1.075 0.93 0.911 0.81 0.775 0.71 0.662 0.62 0.568 0.54 0.490 0.47 0.4233 0.41 0.367 0.36 0.320 0.32 0.280 0.28 0.245 0.25 0.216 0.22 Chapter 9 | Disturbances in comfort NIBE™ F2030...
  • Page 39: Accessories

    Stainless Steel, 1 x 230 V With T&P valve Part no. 069 112 VVM 500 Part no. 069 400 SMO 20 Control module Part no. 067 224 SMO 40 Control module Part no. 067 225 NIBE™ F2030 Chapter 10 | Accessories...
  • Page 40: Technical Data

    600 mm 600 mm Minimum free space Minimum free space Min. avstånd Minimum distance during use vid användning 3000 mm of several F2030 av flera F2030 Fritt utrymme framför Free space in front Chapter 11 | Technical data NIBE™ F2030...
  • Page 41: Sound Pressure Levels

    F2030 is usually placed next to a house wall, which gives a directed sound distribution that should be F2030 works with low fan speed or high fan speed considered.
  • Page 42: Technical Specifications

    Internal pressure drop at nominal flow Max/Min heating medium temp continuous operation °C 65/25 Connection heating medium ext thread G1 (Ø28 mm) Dimensions and weight Width 1260 Depth Height with stand 1134 Weight (excl. packaging) Chapter 11 | Technical data NIBE™ F2030...
  • Page 43 Miscellaneous Enclosure class IP 24 Colour Dark gray Part No. 064 099 064 070 SCOP & Pdesign F2030 according to EN 14825 7 kW 9 kW Pdesign SCOP Pdesign SCOP SCOP 35 Average climate (Europe) SCOP 55 Average climate (Europe)
  • Page 44 Working area Water temperature °C Supply temperature Return temp Outdoor air temperature °C During shorter time it is allowed to have lower working temperatures on the water side, e.g. during start up. Chapter 11 | Technical data NIBE™ F2030...
  • Page 45: Energy Labelling

    The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added to the package, the overall efficiency of the package should be recalculated. NIBE™ F2030 Chapter 11 | Technical data...
  • Page 46 For heat pump combination heater Declared load profile for water heating Water heating energy efficiency ƞ Daily energy consumption 7.59 Daily fuel consumption elec fuel Annual energy consumption 1,667 Annual fuel consumption Chapter 11 | Technical data NIBE™ F2030...
  • Page 47 For heat pump combination heater Declared load profile for water heating Water heating energy efficiency ƞ Daily energy consumption 7.57 Daily fuel consumption elec fuel Annual energy consumption 1,662 Annual fuel consumption NIBE™ F2030 Chapter 11 | Technical data...
  • Page 48: Electrical Circuit Diagram

    Electrical circuit diagram Chapter 11 | Technical data NIBE™ F2030...
  • Page 49 NIBE™ F2030 Chapter 11 | Technical data...
  • Page 50 Chapter 11 | Technical data NIBE™ F2030...
  • Page 51 NIBE™ F2030 Chapter 11 | Technical data...
  • Page 52: Index

    Electrical circuit diagram, 46 Sound pressure levels, 39 Electrical connections, 16 Start-up and inspection, 24 Charge pump, 19 Status channels, 31 Connecting accessories, 22 Stop temperature, 23 Connections, 18 Supplied components, 10 General, 16 Chapter 12 | Item register NIBE™ F2030...
  • Page 53 The heat pump design, 12 Component list electrical cabinet, 14 Component location electrical cabinet, 14 Component locations, 12 List of components, 12–13 Thermostat control, 21 Transport and storage, 7 Troubleshooting, 33 Sensor placement, 34 NIBE™ F2030 Chapter 12 | Item register...
  • Page 55 Återvinning Lämna avfallshanteringen av emballaget till den installatör som installerade produkten eller till särskilda avfallsstationer. När produkten är uttjänt får den inte slängas bland vanligt hushållsavfall. Den ska lämnas in till särskilda avfallsstationer eller till återförsäljare som tillhandahåller denna typ av service. Felaktig avfallshantering av produkten från användarens sida gör att administrativa påföljder tillämpas i enlighet med gällande lagstiftning.
  • Page 56 WS name: -Gemensamt WS version: a74 (working edition) Publish date: 2015-08-31 08:25 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE-285 21 Markaryd info@nibe.se www.nibe.eu 231115...

Table of Contents