1.5: Operating procedure in normal condition

Table: 4 ADOL operating sequence in normal condition
1A
1B
1C
LMR-A
3
Amber
Mode
main
LED
supply
indication
Blink
Manual
ON
(On-delay
duration)
Blink
Auto
ON
(On-delay
duration)
Blink
Bypass
ON
(On-delay
duration)
Starter operation:
LMR-A: Manual mode
1A : Keep the LMR-A in Manual mode.
1B
: Switch ON 3-Phase incoming main supply.
1C : Amber LED will start blinking for a period of min 0.5 min.
1D : 0.5 min is the default setting which can vary from min 0.5 min to max.5min.
1E
: After the ON-delay duration, amber LED will ON continously indicating that the incoming supply
is Healthy (Assuming incoming supply is healthy).
1F
: Press the green push putton for switching ON the starter.
1G : Starter gets switched ON.
1H : Press the red push button for switching OFF the starter.
1I
: Starter gets switched OFF.
1J
: Amber LED indication remains continous ON.
1K : Switch OFF the 3-phase incoming main supply.
1L
: Amber LED indication gets turned OFF indicating that there is no incoming main supply.
LMR-A: Auto mode
1A : Keep the LMR-A in Auto mode.
1B
: Switch ON the 3-Phase incoming main supply.
1C : Amber LED will start blinking for a period of min 0.5 min.
1D : 0.5 min is the default setting which can vary from min 0.5 min to max.5min.
1E
: After the ON-delay duration, amber LED will ON continously indicating that the incoming supply is
healthy(Assuming incoming supply is healthy).
1F
: Not applicable (No need to press ON push button)
1G : Starter gets switched ON automatically.
1H : Press the red push button and lock by mechanical latch for switching OFF the starter.
1I
: Starter gets switched OFF.
1J
: Amber LED indication remains continous ON.
1K : Switch OFF the 3-phase incoming main supply.
1L
: Amber LED indication gets turned OFF indicating that there is no incoming main supply.
1D
1E
On-
Amber
Delay
LED
button
0.5-
ON
5min
0.5-
ON
5min
0.5-
ON
5min
ON operation
1F
1G
1H
'ON'
Starter
'OFF'
Push
Operation
Push
button
ON
ON
OFF
ON
ON
Lock
ON
ON
OFF
1I
1J
1K
Starter
Amber
3
Operation
LED
main
supply
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF operation
1L
Amber
LED
indication
OFF
OFF
OFF
10