Technician Interface Guide; Diagnostic Menu; Description; Accessing The Diagnostic Menu - Victron energy SHS 200 MPPT Manual

Table of Contents

Advertisement

8. TECHNICIAN INTERFACE GUIDE

8.1. Diagnostic menu

8.1.1. Description

The diagnostic menu gives the state of all sensors in the device to ease monitoring and diagnostic.

8.1.2. Accessing the diagnostic menu

Procedure from the Main menu:
1. Press and hold key 3 (WRENCH). It should say "Service Menu".
2. Press 567415 in that order, without pressing anything else.
3. If the procedure is successful, it should say "Diagnostic or (LOCK) for Setup".
4. In case of error, press CANCEL to return to the main menu and repeat the procedure.
Press CANCEL to go back to the main menu.
Press CHECK to view the hardware and firmware versions of the device.

8.1.3. Diagnostic menu map

Once it says ""Diagnostic or (LOCK) for Setup", diagnostic parameters are accessible by pressing keys from 1 to 9:
Key
Parameter
1
USB ports
2
12V DC ports
3
Charging
4
Keypad
5
Usage statistics
6
LCD diagnostic
7
Core clock
8
Temperature Sensor
9
RTC

8.1.4. View hardware and software version

Procedure from the Main menu:
1. Press and hold key 3 (wrench). It should say "Service Menu".
2. Press 567415 in that order, without pressing anything else.
3. If the procedure is successful, it should say "Diagnostic or (lock) for Setup".
4. Press WRENCH to view the hardware and software version of the unit.
5. In case of error, press the X key to return to the main menu, and repeat the procedure.
Press CANCEL to go back to the main menu.

8.2. Setup menu

8.2.1. Description
The setup menu can be used to change some parameters of the device. Most parameters should be left default, apart from the
battery and panel size that should be specified. The other parameters can be adjusted to ease troubleshooting or to provide a
temporary fix to a particular issue.
Page 11
SHS 200 MPPT
Press keys from 1 to 10 to see the current measured at each port.
Current measured at the 5 DC ports.
Voltage and currents of the solar panels (*) and the battery ( )
Type something into keypad to test.
Statistics about device usage. Press any number key to go to the next stat. Press
CANCEL to go back to the Diagnostic menu.
Test characters on the LCD and characters used for the code.
Core clock frequency (72MHz).
Internal temperature of the device.
Internal clock raw time.
Description