4.4.

Activation of control signals

ATTENTION! Material damage!
It may cause damage to the device or the connection ca-
bles, if no higher current strength is ensured.
To avoid this turn the associated PINs of the supply connec-
tions in parallel.
The cross section of the connecting cables is to be dimen-
sioned accordingly to the maximum current (see type plate).
Pin assignment LED powerline AC/IC 410 (15-pin connector)
Function
Supply voltage
U
= 45V - 55V
b+
Supply voltage GND
PLC ON
PLC GND
PLC LEDenable
analog set point SW +
analog set point SW -
PLC Out OK
PLC Out ON
PLC Out OFF
PLC Out COM
TxD +
TxD -
RxD +
RxD -
PWM
#078734DE-EN e
Description
Power connection
(I
see7.2 Dimensions,
max
electrical values page 23)
Input LED ON
GND for PLC
Input LEDenable
set point
0 – 10V ≙ 0 – 100%
GND for set point
status signal of the LED
Transmit Data
Receive Data
Fan control
Control signals
PIN
1
15
2
6
13
10
15
7
9
14
8
11
3
4
12
5
15