3. Control Diagrams For Turning On / Turning Off Different Heat and Cool Stages
Control Diagram 5: Heat Pump 3-Stage Heat With Auxiliary Heat (allowed to run with other heat stages), 2-Stage Cool
3 (Aux)
On
Heat
Stages
2
(Fan On)
1
HSP-H3N
Control Diagram 6: Heat Pump 3-Stage Heat With Auxiliary Heat (NOT allowed to run with other heat stages), 2-Stage Cool
Heat pump cannot run
On
Heat
Stages
2
Off
(Fan On)
1
Off
Note: If Aux / W
heat is delayed due to an upstage timer, stage 1 and 2heat will continue until auxiliary can turn on.
2
Included with SMC55-HWQS version 7420 or newer, SMC55-RESI version 7302 or newer and HomeWorks Palladiom Thermostat version 1.10 or newer.
1
Off
On
Off
On
Off
HSP-H2N
HSP-H1N
HSP
HSP+H1F
Heating
Cooling
with gas on
Off
On
Off
Stays off while gas is on
On
Off
HSP-H2N
HSP-H1N
HSP
HSP+H1F
Heating
Cooling
Off
On
On
Off
CSP-C1F
CSP
CSP+C1N
CSP+C2N
Off
On
On
Off
CSP-C1F
CSP
CSP+C1N
CSP+C2N