Lutron Electronics PALLADIOM Configuration Manual page 32

Table of Contents

Advertisement

Appendix A
(continued)
3. Control Diagrams For Turning On / Off Different Heat and Cool Stages
The control diagrams below graphically represent the on / off deltas for different heating and cooling stages.
Table 19: Default Values for Heat and Cool Stages
Heat & Cool Stage
H1N: Heat Stage 1 on Delta
H1F: Heat Stage 1 Off Delta
H2N: Heat Stage 2 On Delta
H2F: Heat Stage 2 Off Delta
C1N: Cool Stage 1 On Delta
C1F: Cool Stage 1 Off Delta
C2N: Cool Stage 2 On Delta
C2F: Cool Stage 2 Off Delta
Control Diagram 1: Conventional or Heat Pump 1-Stage Heat, 1-Stage Cool
Heat
Stages
(Fan On)
1
Control Diagram 2: Heat Pump 2-Stage Heat, 2-Stage cool (No Auxiliary)
Heat
Stages
2
(Fan On)
1
1
Included with SMC55-HWQS version 7420 or newer, SMC55-RESI version 7302 or newer and HomeWorks Palladiom Thermostat version 1.10 or newer.
Continued on next page...
Advanced
Default
Parameter
Value
(74A)
1
(75A)
1
(76A)
2
1
(77A)
2
1
(80A)
1
(81A)
1
(82A)
2
1
(83A)
0
1
On
Off
HSP-H1N
HSP
HSP+H1F
Heating
Cooling
On
Off
On
Off
HSP-H2N
HSP-H1N
HSP
HSP+H1F
Heating
Cooling
Off
On
CSP-C1F
CSP
CSP+C1N
1
Off
On
On
Off
CSP-C1F
CSP
CSP+C1N
CSP+C2N
32
P/N 032498h
Cool
Stages
(Fan On)
1
Cool
2
Stages
(Fan On)
1

Advertisement

Table of Contents
loading

Table of Contents