Step 5: Set the SMC55-HWQS Advanced Parameters to Modify the
Functionality of the HVAC System
Table 16: Advanced Configuration Parameters for the SMC55-HWQS (continued)
Advanced
Applicable
Configuration
Systems
Parameter
78A
79A
80A
81A
82A
83A
Heat
Pump
and
1
Conventional
84A
85A
Heat
88A
Pump
1
90A
91A
Radiant
92A
Floor
1
93A
94A
Included with SMC55-HWQS version 7420 or newer and HomeWorks Palladiom Thermostat version 1.10 or newer.
1
Continued on next page...
Name
Description
°F below setpoint to turn stage on. If auxiliary is stage 2, this
Aux / W
On
differential is used to turn on.
2
°F above setpoint to turn stage off. If auxiliary is stage 2, this
Aux / W
Off
differential is used to turn off.
2
Cool Stage 1 On
°F above setpoint to turn stage on.
Cool Stage 1 Off
°F below setpoint to turn stage off.
Cool Stage 2 On
°F above setpoint to turn stage on.
Cool Stage 2 Off
°F below setpoint to turn stage off.
Stage 2 cooling will not turn on until the first stage has run
Compressor
for the chosen duration.
Cool Stage 2
0: 0 minutes, 1: 1 minute, 2: 2 minutes, 3: 5 minutes,
Upstage Delay
4: 10 minutes, 5: 20 minutes, 6: 30 minutes, 7: 1 hour,
8: 2 hours, 9: 4 hours, 10: 8 hours, 11–99: 11–99 hours
Stage 2 compressor heating will not turn on until the first
Compressor
stage has run for the chosen duration.
Heat Stage 2
0: 0 minutes, 1: 1 minute, 2: 2 minutes, 3: 5 minutes,
Upstage Delay
4: 10 minutes, 5: 20 minutes, 6: 30 minutes, 7: 1 hour,
8: 2 hours, 9: 4 hours, 10: 8 hours, 11–99: 11–99 hours
Delay to wait for reversing valve to change over. When changing
Reversing
between heat and cool, the thermostat will turn off the
Valve Delay
compressor, then wait for MCOT. The thermostat will then change
(RVD)
the state of the O/B signal, and wait for the reversing valve delay
(RVD) before turning the compressor and fan back on.
If slab temperature rises above this maximum, must turn off
Slab Maximum
regardless of air temperature.
If slab temperature falls below this minimum, must turn on
Slab Minimum
regardless of air temperature.
Floor 100%
Differential
°F below the setpoint to turn on system to 100%.
Temperature
Floor 0%
Differential
°F above the setpoint to turn on system to 0%.
Temperature
Cycles Per Hour
Cycles per hour (CPH).
(continued)
21
P/N 032498h
Default Value
Range
3 °F
1 °F – 10 °F
0 °F
1 °F – 10 °F
1 °F
1 °F – 10 °F
1 °F
1 °F – 10 °F
2 °F
1 °F – 10 °F
0 °F
1 °F – 10 °F
0 – 99
0 minutes
minutes
0 minutes, however
0 – 99
thermostat will default
minutes
based on stages
0 – 99
1 second
seconds
85 °F
0 – 120 °F
60 °F
0 – 120 °F
2.0 °F
0 – 20 °F
2.0 °F
0 – 20 °F
3 (20 minute signal period)
1-20 CPH