biochrom Libra S50 Health & Safety Manual

biochrom Libra S50 Health & Safety Manual

Uv visible spectrophotometers

Advertisement

Biochrom Libra S50, S60, S70 & S80
UV Visible Spectrophotometers
Health & Safety Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Libra S50 and is the answer not in the manual?

Questions and answers

Summary of Contents for biochrom Libra S50

  • Page 1 Biochrom Libra S50, S60, S70 & S80 UV Visible Spectrophotometers Health & Safety Manual...
  • Page 2 DECLARATION OF CONFORMITY This is to certify that the following Biochrom manufactured products conform to the requirements of the following Directives -: Biochrom Libra S50 (80-7000-00, 80-7000-01, 80-7000-02, 80-7000-03, 80-7000-04) Biochrom Libra S60 (80-7000-10, 80-7000-11, 80-7000-12, 80-7000-13, 80-7000-14) Biochrom Libra S70 (80-7000-20, 80-7000-21, 80-7000-22, 80-7000-23, 80-7000-24)
  • Page 3: Table Of Contents

    CONTENTS: HEALTH & SAFETY General Safety General Hazards Unpacking & Installation Instrument Connections Equipment Operation Controls and Indicators Intended Users Instrument Preparation Post Run Procedures Performance Validation User Maintenance Troubleshooting Service Contacts Service, Repair or Return Disposal...
  • Page 4: Health & Safety

    HEALTH & SAFETY General safety This equipment has been designed to conform to the following directives 2006/95/EC Low Voltage Equipment Safety Directive 98/79/EC In Vitro Diagnostic Medical Devices Directive 2004/108/EC EMC Directive 2002/96/EC EC Directive on Waste Electrical and Electronic Equipment (WEEE) 2003/108/EC, 2008/34/EC 2002/95/EC Restrictions of the use of certain Hazardous Substances in electrical and...
  • Page 5 The UV source contained within the unit generates a light beam that traverses the sample chamber and is accessible in the lamp chamber. Under normal use the lamp beam is confined within the instrument. The unit should not be operated with the sample chamber lid open or the lamp housing lid removed.
  • Page 6: Unpacking & Installation

    Unpacking and Installation  These instruments weigh approximately 18.5kg. Follow you local regulations for safe handling and lifting of this equipment.  Inspect the instrument for any signs of damage caused during transit. If any damage is discovered. Do not use the instrument and report the problem to your supplier. ...
  • Page 7: Instrument Connections

    Instrument Connections...
  • Page 8: Equipment Operation

    Equipment Operation Controls and Indicators INTENDED USERS The instrument is intended to be used by scientists and technicians who possess basic laboratory and technical skills and have the knowledge and understanding of the hazards involved, with the unit and the samples used, to operate it in a safe manner. Instrument Preparation ...
  • Page 9: Post Run Procedures

    correct type. Some cells absorb in the UV and are not suitable for UV sample measurement. Cells used for samples should be free from dust, residue or scratches.  Before preparing samples and sample reference blanks, you must be familiar with hazards arising from handling the sample materials and where necessary observe local regulatory practice, personnel protection equipment and measures designed to ensure your safety.
  • Page 10: Troubleshooting

    advised to have the lamps changed. Deuterium and Tungsten lamps may be replaced by the user. Xenon lamp replacement can only be carried out by a qualified service engineer.  To replace a Deuterium or Tungsten lamp ; o Switch the instrument off, disconnect the power supply cord and allow lamps to cool. o Locate the lamp access cover at the rear of unit and remove the two top screws and slide top cover back and lift off.
  • Page 11: Service Contacts

    Customer Support Contacts Note: If you experience any problems with your instrument, please refer to the troubleshooting guide on page 8. If you require further assistance, please contact customer support at http://www.biochrom.co.uk/content/1/11/support.html Customer Support ROW +44 (0)1223 427890 support@biochrom.co.uk Customer Support US support@biochrom.co.uk...
  • Page 12 41 56 1872 issue 01...

This manual is also suitable for:

Libra s60Libra s70Libra s80