Keysight Technologies N1913PM5B Product Note

Keysight Technologies N1913PM5B Product Note

Calorimetric power meter

Advertisement

Quick Links

Keysight Technologies
N1913PM5B
Calorimetric Power Meter
Product Note

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the N1913PM5B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Keysight Technologies N1913PM5B

  • Page 1 Keysight Technologies N1913PM5B Calorimetric Power Meter Product Note...
  • Page 2: Safety Notices

    DOCUMENT THAT CONFLICT WITH government requirements THESE TERMS, THE WARRANTY beyond those set forth in the © Keysight Technologies, Inc. 2020 TERMS IN THE SEPARATE EULA shall apply, except to the AGREEMENT WILL CONTROL. No part of this manual may be...
  • Page 3 Note: The tapers shown in the picture are optional accessories and are not provided, unless ordered with the PM5B. The power line cord shown is ordered for the country of use and is supplied outside the Pelican case as an accessory. Keysight N1913PM5B Product Note...
  • Page 4: Key Features

    PM5B Calorimetric mm-Wave Power Meter Product Note Description N1913PM5B is a Virginia Diodes, Inc./Erickson PM5B calorimetric mm-wave power meter, with a W-Band sensor for power measurement over a frequency range of 75-110 GHz. Additional waveguide tapers are available to enable measurement of power up to 1.5 THz.
  • Page 5 WR1.5 Waveguide Taper, WM380 500-750 GHz N1913PM5B-01B 1.5 dB WR1.0 Waveguide Taper, WM250 750-1100 GHz N1913PM5B-001 2.1 dB WR0.65 Waveguide Taper, WM164 1.1-1.5 THz N1913PM5B-065 1. Tapers are optional. They can be ordered with the N1913PM5B. Keysight N1913PM5B Product Note...
  • Page 6 N1913PM5B with Sensor and Cable Connected to the Front Panel Figure 2 N1913PM5B with Power Supply and USB Cable Connected to the Rear Panel The USB connection is usually very snug and may require some additional pressure to insert or remove completely.
  • Page 7: Operation Example

    Banana jacks for DC calibration. (max 15V) Internal Calibration Power ON/OFF Switch Switch (100 µW to Toggle switch. 100 mW) USB Interface Analog Output Type B jack. BNC to other equipment. (-10 to +10 VDC) DC Power Input (9V, 4A) Keysight N1913PM5B Product Note...
  • Page 8 8. Set the Internal Calibration Switch on the rear panel to 1 mW and read the meter at 1.000 ± .050 (allow meter to settle before and after setting switch. This verifies the N1913PM5B is functioning correctly). 9. Turn off the Internal Calibration Switch (OFF/EXT).
  • Page 9 0.6 seconds 0.03 µW 12 seconds 0.003 µW 200 µW 1. Response time is given as the time from the application of an input to a response at the analog output of 90% of the final reading. Keysight N1913PM5B Product Note...
  • Page 10 Data Port (nom.) 4 1/2 digit LED Display (nom.) ± 10 Volts (BNC connector) Analog Output (nom.) 100 - 240 Volts, 50 - 60 Hz, 1.2 A AC Power Input (spec.) AC plug (per country, C13) Keysight N1913PM5B Product Note...
  • Page 11 Table 4 PM5B Mechanical Dimensions Item Size 5.1 x 4.8 x 7.6 cm Sensor ~ 8.9 x 15.2 x 26.7 cm Power meter Table 5 PM5B Environmental Specifications Specification Range Operating temperature (spec.) 10 - 30 °C Keysight N1913PM5B Product Note...
  • Page 12 USB Cable Connection to the Rear Panel of the Power Meter The USB connection is usually very snug and may require some additional pressure to insert or remove completely. Figure 7 USB Cable Connection to the Rear Panel of the Analyzer Keysight N1913PM5B Product Note...
  • Page 13 2. On the analyzer front panel, press the CAL key to bring up the screen shown in Figure 8. Figure 8 Press the CAL key 3. On the display screen, press the Other Cals softkey (Figure 9). Figure 9 Select "Other Cals" Keysight N1913PM5B Product Note...
  • Page 14 4. On the display screen, select the Source Power Cal... softkey (Figure 10). Figure 10 Select "Source Power Cal..." 5. On the display screen, select the Power Meter Config button (Figure 11). Figure 11 Select "Power Meter Config" Keysight N1913PM5B Product Note...
  • Page 15 6. When the Power Meter Settings window comes up, select Any and in the VISA resource string/alias bar, type "ASRL3::INSTR" as shown in Figure 12. Figure 12 Power Meter Settings 7. Select OK to begin the power meter calibration. Keysight N1913PM5B Product Note...
  • Page 16 Keysight N1913PM5B Product Note...
  • Page 17: Keysight Support, Services, And Assistance

    If there is any physical damage, refer “Contacting Keysight” below. Keep the damaged shipping materials (if any) for inspection by the carrier and a Keysight Technologies representative. When shipping, use original packaging or comparable. Contacting Keysight...
  • Page 18 This information is subject to change without notice. © Keysight Technologies 2020 Edition 2, July 2020 Supersedes: March 2020 www.keysight.com...

Table of Contents