Top Up Central Lubrication - Optimum Optigring GT 25 Operating Manual

Surface grinding machine
Table of Contents

Advertisement

3.10

Top up central lubrication

The machine has a central lubrication system.
Fill the container with slideway oil up to the
"MAX" mark.
When the machine is in operation, the oil
pump supplies the slideway oil to all lubrica-
tion points simultaneously at the entered time
interval (2) in minutes and the entered time
period (1) in seconds.
Suitable slideway oil is ISO VG 32 or ISO VG
68.

Lubricant on page 157
SET button
To reset the pump or cancel the alarm.
To set the time duration and interval:
Press and hold SET key for 2 seconds to
set the pump operating time (shown on
the display as ACT)
The adjustable running time of the pump is
1 to 999 seconds.
To set the interval:
Press and hold the SET key again for 2 seconds to set the pump interval duration (dis-
played on the screen as INT).
The adjustable interval time is 1 to 999 minutes.
Press and hold the button a third time for 2 seconds to complete the setting.
Rst button
The same function as the SET button to cancel the alarm.
Version 1.0.2 - 2020-09-15