Verkada AC41 Installation Manual page 8

4-door controller
Hide thumbs Also See for AC41:
Table of Contents

Advertisement

VERKADA INC
INSTALLATION
Connecting a Door
This section takes you through how to connect a door to your AC41.
Before Getting Started
WARNING!
Ensure power is disconnected from the AC41 and locking hardware before wiring readers and other devices.
Failure to do so can damage the AC41.
The AC41 comes equipped with a Form C relay that can be driven dry or wet. AC41 is rated to power 12V locks up to
700mA and 24V locks up to 350mA.
1
Wiring Fail Secure and Fail Safe Locking Hardware
Fail secure and fail safe are ways of configuring
locking hardware:
Fail secure hardware locks when power is
interrupted. Usually uses NO (Normally Open
Configuration)
Fail safe hardware unlocks when power
is interrupted. Usually uses NC (Normally
Closed configuration)
2
Remove the Cassettes
Begin by removing a door cassette from the
AC41 by lifting it from the side tabs.
7
CONFIDENTIAL
Keep in mind that some door strikes can be wired as
fail safe and some electromagnetic locks can be fail
secure; always check your third-party locking hard-
ware wiring instructions and ensure you're using the
right configuration for your requirements.
Verkada Inc. 405 E 4th Ave, San Mateo, CA, 94401
sales@verkada.com
AC41 — INSTALLATION MANUAL
All specifications are subject to change without notice.
Copyright © Verkada Inc . All rights reserved.