With temperature control: ambient temperature sensor enabled
Example 1: [button B] is set to Output Level 3, the temperature setting is 22°C, the stove will heat at Output Level 3
until the measured room temperature reaches 22 °C and then, will automatically reduce to Output Level 1 so as not
to overheat the room.
Example 2: [button B] is set to Output Level 5, the temperature setting is 25°C, the stove will heat at Output Level 5
until the measured room temperature reaches 25 °C and then, will automatically reduce to Output Level 1 so as not
to overheat the room.
Please note:
•
The stove will not shut down automatically: It will remain at Output Level 1 even if the temperature setting is
exceeded.
•
In this case, if the heating requirements are lower than Output Level 1, the room temperature may continue
to increase . (in between seasons in particular)
•
Turn off the stove as necessary by pressing [button A].
Page 27 sur
XD, on 14/05/2018
ARATOS Plug-in
Recommended setting 15 to 30°C
Choose the required temperature setting with [button D]
•
in this example: 22 °C
The output indicators are lit at "maximum possible output"
•
as in the example "Output Level 3"
•
If the recommended temperature is exceeded, the 3 LEDs will flash to
indicate that the temperature is being regulated, the output will decrease to Output
Level 1 to avoid overheating the room.
•
•
If the requested Output Level is 2, 2 LEDs will flash during output regulation,
4 LEDs will flash if the requested Output Level is 4 etc...
Choose the maximum possible Output Level with the [Button B]:
•
In this example "Output Level 3": The stove will operate between levels 1 and 3
depending on the difference between the desired temperature and the measured
ambient temperature.
To turn off completely, press [button A]:
•
"Power On LED" starts flashing
41
stove
dual
model 6490 00