About The Access Points (Rfp's); Point (Rfp') - Aastra SIP-DECT Installation And Administration Manual

Aastra sip-dect: user guide
Hide thumbs Also See for SIP-DECT:
Table of Contents

Advertisement

Installation, Administration and Maintenance
2.2

About the Access Points (RFP's)

Aastra has two versions of Access Points, indoor and outdoor models RFP32
and RFP34 respectively. RFP references apply to both models.
In general all RFPs have the same hardware and software capabilities.
Please be aware of the regulatory differences between North America and
all other areas of the world . These differences lead to different RFP variants
which use specific frequency bands and field strengths:
• RFP 32 IP or RFP 34 IP (EMEA)
Frequency Band 1.880 to 1.900 Mhz
-
-
10 carrier frequencies
Transmit Power 24 dBm
-
• RFP 32 NA or RFP 34 NA (NA)
Frequency Band 1.920 to 1.930 Mhz
-
5 carrier frequencies
-
-
Transmit Power 20 dBm
One RFP within a SIP-DECT installation must be declared to operate as the
OpenMobility Manager (OMM). The RFP acting as the OMM may also act as
a regular RFP as well if it is included into a DECT Cluster.
Aastra Telecom
Page: 9 (47)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents