Available languages

Output Specifications
Output cable
Use a shielded cable as shown to connect to the output
connector. Connect the shielded wire on the interpolator
end of the cable to the case of the output connector.
Make the cable length as short as possible to improve noise
immunity.
Cross section of the cable
Open collector output (MJ110)
. Use an output cable with a thickness of AWG26 or 28 and
a length of 30 m or less.
. Make sure that the power supply voltage is 11 V DC to
31 V DC at the input terminal to the interpolator.
Outer coating
Outputs : A/B phase,
Reference point signal,
Alarm signal
U/ V/ W phase
Shield
Voltage-differential line drivers output (MJ100)
. Use the MC34C86 or its equivalent for the receiver circuit.
. Make sure that the power supply voltage is in the range
4.5 V DC to 6 V DC at the input terminal to the interpolator.
50 m/164' or less
MJ100
Twisted pair (28 AWG or thicker)
+5 V
0 V
Receiving
device
(E) 15