3. Start the engine.
4. Press and hold the RPM SET button.
When you push the SET RPM button
will see the "RPM Set" LED illuminate.
5. With another person helping you, have
them step on the accelerator with the
vehicle in park. Raise the engine RPM
to 1200 RPM.
6. Release the SET RPM button.
Upon releasing the button the unit will
store the RPM + 25%.
example the unit has stored 1320 RPM
+ 25% = 1650 RPM.
7. Now increase the RPM of the engine
to test the activation circuit is working
correctly. As in this example the valve
should activate at 1650 RPM.
8. With the valve activated the engine
should die. Reset the valve and restart
the engine.
9. Press and hold the RPM SET button.
When you push the SET RPM button
will see the "RPM Set" LED illuminate.
10. With another person helping you, have
US Shipping Address: 88-446 Harrison St, Sumas, WA 98295 US Mailing Address: PO Box 231, Sumas, WA 98295
Ford 6.7L 2011-2012 Positive Air Shutoff
So for this
BD ENGINE BRAKE, INC.
Plant Address: A10-33733 King Rd, Abbotsford, BC, Canada V2S 7M9
Phone: 604-853-6096 Fax: 604-853-8749 Internet: www.bd-power.com
PRESS &
Set
Button
RPM Set
RELEASE TO
STORE RPM
RPM Set
You should see the RPM signal flash
proportionally to engine RPM.
You should see the ACTIVATION
LED flash ON/OFF on activation.
If the valve does not activate check
the wiring.
If the valve activates but the engine
does not stall, ensure nothing has
contacted the valve linkage.