Obsidian at a Glance
Exterior
Touchscreen
Checkmark
Lock
symbol
symbol
Emergency
Power 9 Volt Port
Switches and Status LED Colors
Switches
On
Off
1 2 3 4
Switch
Function
1
Door lock status LED blinks every 6 seconds
Lock automatically re-locks door 30 seconds after
2
unlocking. Disabled if no codes are programmed.
3
Audio
SecureScreen feature displays random digits to be
pressed before entering user code. This added-
4
security feature ensures that there are fingerprints
on all digits so that codes cannot be identified by
examining the touchscreen for fingerprints.
Deleting a single user code
Note: All codes may be deleted at once if the mastercode is enabled. For more information about the
mastercode, consult the online Programming and Troubleshooting Guide.
1 Keep door open.
2 Press Checkmark
Press Program
symbol once.
button once.
5 Press Lock symbol
6 Re-enter user code.
once.
If the screen is not pressed for 20 seconds, the system will time out, and you will need to restart the procedure.
Low Battery
If the 4 AA batteries are too low to operate the lock,
use a 9-Volt Alkaline battery to temporarily power the
touchscreen.
Make sure both terminals on the 9-Volt battery touch the
terminals at the bottom of the touchscreen. Hold the 9-Volt
in place while entering your user code to unlock the door.
Continue holding the 9-Volt in position until the Checkmark
symbol illuminates and the door unlocks.
Note: If you remove the battery before the Checkmark
symbol illuminates, you will need to re-enter your user code
Reference Guide
Interior (cover removed)
Back
panel
Button "A"
Button "B"
Program
button
Switches
Status
LED
Turnpiece
shaft
Note: When the cover is removed,
the turnpiece shaft can be used to
manually lock and unlock the door.
Status
LED
Color
Lock Status
Blinking green
Unlocked
Blinking amber
Locked
Blinking red
Low battery
3 Press Lock symbol
4 Enter user code to
once.
be deleted.
If unsuccessful
7 Press Lock symbol
once.
Make sure to enter
the same valid code in
steps 4 and 6.
Test code
While the door is open,
test the user code to
make sure it no longer
unlocks the door.
Network Information
Removing the lock from the network
Press button "B" on the lock interior nine times.
ZigBee System Notes
Zibee is a "Wireless mesh network", and results may vary based on
building construction and communication path with 36+ feet being
typical installed distance in a standard home environment and 250+
feet when the lock has a clear line of sight with the smart home
controller. It may be necessary to install additional Zigbee devices to
enhance the communication path between the lock and controller for
a more robust ZigBee network.
System Alerts
Display
Alert
Reason
"X" pattern flashes one
One incorrect code entered.
time with one beep*.
No user code programmed.
"X" pattern flashes
Programming timeout after
three times with three
20 seconds.
beeps*.
Unsuccessful programming.
"X" pattern flashes 15
Three incorrect codes
times with 15 beeps*
entered within one minute.
Checkmark and
lock symbols flash
simultaneously five
Low battery.
times with long
continuous beep*.
Checkmark and lock
symbols alternate
Door jammed while
flashing five times with
attempting to lock.
long continuous beep*.
Lock beeps
Interior assembly is
N/A
continuously.
disconnected from exterior.
Manual Door Handing
If needed, the door handing process can be initiated manually.
This is useful if the lock is being moved to a different door.
1 Remove
2 Press and HOLD the Program
battery pack.
3 Press the Program
4 The latch bolt
button once more.
Factory Reset
A factory reset will delete all codes associated with the lock, and it will
remove it from your smart home system.
1 Remove
2 Press and HOLD the Program
battery pack.
3 Press the Program button
once more. The status
LED will flash green and
red several times.
Important Safeguards
1.
Read all instructions in their entirety.
2. Familiarize yourself with all warning and caution statements.
3. Remind all family members of safety precautions.
4. Protect your user codes and mastercode.
5. Dispose of used batteries according to local laws and regulations.
CAUTION: Prevent unauthorized entry. Since anyone with
access to the back panel can change the user codes, you must
restrict access to the back panel and routinely check the user
codes to ensure they have not been altered without your
knowledge. The use of a mastercode can help protect your
system's settings.
WARNING: This Manufacturer advises that no lock can provide
complete security by itself. This lock may be defeated by
forcible or technical means, or evaded by entry elsewhere on
the property. No lock can substitute for caution, awareness of
your environment, and common sense. Builder's hardware is
available in multiple performance grades to suit the application.
In order to enhance security and reduce risk, you should
consult a qualified locksmith or other security professional.
4 / 4
Solution
Re-enter code.
Program at least one user code.
Attempt programming procedure again.
Re-enter code after 60 second
touchscreen lockout.
Replace batteries.
Manually re-lock door. If needed,
reposition strike.
Remove battery pack, reconnect the interior
to the exterior, then replace battery pack.
*Beeping sound will only be heard if switch #3 is on.
button while reinserting the
battery pack.
Release button once battery
pack is installed. The status LED
will flash red and green.
Status
LED
will extend and
retract to learn
the orientation
of the door.
Success
If the touchscreen indicates a failure, see the
online Programming and Troubleshooting Guide
or call Technical Support.
button while reinserting
the battery pack.
Keep holding the button for 30
seconds until the lock beeps
and the status LED flashes red.
Status
LED
4 After a few seconds, the lock will
initiate the door handing process, and
the latch bolt will extend and retract
to learn the orientation of the door.
© 2018 Spectrum Brands, Inc.
Failure

Advertisement

loading

This manual is also suitable for:

954 obn zb-amz 15 smtcd