Emerson Dosaodor-D V page 30

Odorant injection system
Table of Contents

Advertisement

Dosaodor-D
Loc:14 Dosaodor-D Rev. 4.17
a) Previous Month Gas Volume
b) Previous Month Odorant Vol.
c) Previous Month Aver. Con.
a) Previous Month Gas Volume
The gas volume achieved between "Contractual Hour
Day End" of the first day and "Contractual Hour Day End"
of the last day of the previous month is displayed
b) Previous Month Odorant Volume
The odorant volume achieved between "Contractual
Hour Day End" of the first day and "Contractual Hour Day
End" of the last day of the previous month is displayed.
c) Previous Month Average Concentration
The average concentration of odorant in the gas
is displayed (ratio between the quantity of odorant
injected and the volume of transited gas) calculated
between "Contractual Hour Day End" of the first day
and "Contractual Hour Day End" of the last day of the
previous month.
Loc:15 Dosaodor-D Rev. 4.17
a) Odorant Cylinder Vol. Used
b) Remaining Od. Vol. for I1 ↔ I2.
c) Current Odorant Con.
a) Odorant Cylinder Volume Used
Indicates the quantity of odorant theoretically collected
from the control cylinder (sampler) which is installed on
the Dosaodor-D pneumatic panel.
* This value is indicated in letters "H" / "L" / "R" meaning:
"H" Dosaodor-D detect High Level inside of Control Cylinder
"L" Dosaodor-D detect Low Level inside of Control Cylinder
"R" Dosaodor-D has Recharging Control Cylinder valve Open
b) Remaining Value for Switch Injector 1 ↔ Injector 2
Indicates the odorant value to be injected prior to the au-
tomatic exchange between Injector 1 and 2 takes place.
The exchange takes place only if the Injector 1-2 mode
has been selected on Dosaodor-D B.2 (dual injectors).
c) Current Odorant Concentration
Indicates the instantaneous concentration of odorant in
the gas (ratio between the quantity of injected odorant
and the volume of transited gas). It is calculated
considering the volume of odorant inserted with the last
10 injections and relevant gas volumes integrated in the
same period. This value is updated each 10 seconds and
is used to generate the analog output signal 4-20 mA
(range 0-100 mg/m
3
)
30
m
3
00000000
g
00000000
mg/m
000.0
3
g
000.00 *
g
00000000
mg/m
3
000.0
Print Menu: Loc:20
(it can be open also by pressing PRN Key)
Loc:20 - DATA PRINTING MENU -
a) 1) PRINTING Programmed Data
b) 2) PRINTING Daily Report
c) 3) PRINTING Event Report
a) 1) PRINTING Programmed Data
By pressing the "1" key, the data programmed in
Dosaodor-D are printed.
Date: xx/xx/xx Time: xx:xx Code: xxxxxxxx
PROGRAMMED DATA
Software Version 4.17
Programmed Date
Programmed Time
Odorizing Concentration
Gas Volume Input
Gas Flowrate (Manual Set)
Specific Volume Inject. N1
Specific Volume Inject. N2
Check Cylinder Od. Volume
Volume of Switch I1 ↔ I2
User Code
Printer Interval
Odorize Volume in the Tank
Low Odorant Level Tank
Odorant Specific Weight
Pulse Output Odorize
Pulse Output Gas
Contractual Hour Day End
F.S. Flowrate Gas (4 – 20 mA)
Installed Modem Type
b) 2) PRINTING Daily Report
By pressing key "2", the daily report is printed. The
format is identical to the one used for the Automatic
Report of the End of the Day. The only difference is in the
printed values, which are updated at the time of printing
and not at the end of the "Contractual Hour Day End".
Date: xx/xx/xx Time: xx:xx Code: xxxxxxxx
PRINT BY OPERATOR
DAILY REPORT OF................. ..: xx/xx/xx
DAILY DIAGNOSTIC...................: xxxxxxxx
Present Day Gas Volume
Present Day Odorant Volume
Present Day Aver. Conc.
PARTIAL MONTHLY REPORT OF:
Present Month Gas Volume
Present Month Odorant Vol.
Present Month Aver.Conc.
xx/xx/xx
xx:xx:xx
mg/m
3
40
1 Pulse=m
3
0010.00
m
/h
00001000
3
g/s
01.00
g/s
01.00
g
0062.0
g
00002000
Number
00000000
Hour:Minute
00:00
l
0100
l
000
kg/l
1.00
Imp.=g
001
Imp.=m
3
0010
0-23
00
m
00000000
3
No - Modem
m
3
00000000
g
00000000
mg/m
3
000.1
xx/xx
m
00000000
3
g
00000000
mg/m
3
000.1