Remote Update Using Loggernet - Campbell CR300 Series Application Note

Cellular module firmware update
Hide thumbs Also See for CR300 Series:

Advertisement

If State shows Network ready, try this procedure again from the beginning. If State shows a
message that the firmware update is still in process, allow the process to complete before
powering down the data logger. It could take several hours to complete.
4. Remote update using
LoggerNet
This is the best method to use if using the Konect PakBus® Router service to access the
CR3X0-CELL2XX device. It is assumed that the data logger is already set up in the LoggerNet
Setup screen. If this has not been done, you will need to do so.
1. From the Connect window, click Station Status to confirm the Operating System version is
08.01 or greater. If it is not, see
CR300 OS update
(p. 2).
Cellular Module Firmware Update
8