1 About the documentation
16.1.1
About making field settings ......................................... 29
16.1.2
16.1.3
Field setting components ............................................ 29
16.1.4
To access mode 1 or 2 ............................................... 30
16.1.5
To use mode 1 (and default situation) ........................ 31
16.1.6
To use mode 2 ............................................................ 31
16.1.7
16.1.8
Mode 2: Field settings................................................. 33
16.1.9
unit .............................................................................. 36
17.1
Precautions when commissioning ............................................. 36
17.2
Checklist before commissioning................................................ 36
17.3
Checklist during commissioning ................................................ 37
17.3.1
About the test run........................................................ 37
17.3.2
To perform a test run (7-LEDs display)....................... 37
17.3.3
17.3.4
17.3.5
Operating the unit ....................................................... 38
19.1
Solving problems based on error codes.................................... 38
19.1.1
Error codes: Overview ................................................ 39
20.1
20.2
Wiring diagram: Compressor unit.............................................. 43
1
About the documentation
1.1
About this document
Target audience
Authorised installers + end users
INFORMATION
This appliance is intended to be used by expert or trained
users in shops, in light industry and on farms, or for
commercial use by lay persons.
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
▪ Safety instructions that you must read before installing
▪ Format: Paper (in the accessory bag of the compressor unit)
▪ Compressor unit installation and operation manual:
▪ Installation and operation instructions
▪ Format: Paper (in the accessory bag of the compressor unit)
▪ Heat exchanger unit installation manual:
▪ Installation instructions
▪ Format: Paper (in the accessory bag of the heat exchanger
unit)
▪ Installer and user reference guide:
▪ Preparation of the installation, reference data,...
▪ Detailed step-by-step instructions and background information
for basic and advanced usage
▪ Format: Digital files on
http://www.daikineurope.com/support-
and-manuals/product-information/
Installation and operation manual
6
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
Technical engineering data
▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
36
2
Specific installer safety
instructions
Always observe the following safety instructions and regulations.
WARNING
Tear apart and throw away plastic packaging bags so that
38
nobody, especially children, can play with them. Possible
risk: suffocation.
38
CAUTION
Appliance not accessible to the general public, install it in a
secured area, protected from easy access.
42
This unit, both indoor and outdoor, is suitable for
installation
in
environment.
44
CAUTION
Excessive refrigerant concentrations in a closed room can
lead to oxygen deficiency.
DANGER: RISK OF ELECTROCUTION
Do NOT leave the unit unattended when the service cover
is removed.
DANGER: RISK OF BURNING/SCALDING
DANGER: RISK OF ELECTROCUTION
WARNING
Take sufficient precautions in case of refrigerant leakage. If
refrigerant gas leaks, ventilate the area immediately.
Possible risks:
▪ Excessive refrigerant concentrations in a closed room
can lead to oxygen deficiency.
▪ Toxic gas might be produced if refrigerant gas comes
into contact with fire.
WARNING
ALWAYS recover the refrigerant. Do NOT release them
directly into the environment. Use a vacuum pump to
evacuate the installation.
WARNING
During tests, NEVER pressurize the product with a
pressure higher than the maximum allowable pressure (as
indicated on the nameplate of the unit).
CAUTION
Do not vent gases into the atmosphere.
a
commercial
and
light
RKXYQ5T8 + RKXYQ8T7Y1B
VRV IV compressor unit for indoor installation
4P499900-1A - 2020.10