21 Disposal

S*S
Cool/heat selector switch (optional)
V1R
IGBT power module (A2P)
V2R
Diode module (A2P)
X1M
Terminal strip (power supply)
X2M
Terminal strip (transmission wiring)
X*Y
Connector
Y3E
Electronic expansion valve
Y1S
Solenoid valve (4‑way valve)
Z*C
Noise filter (ferrite core)
Z*F
Noise filter (A1P)
Notes for 8 HP:
1
When using the optional adapter, refer to the installation
manual of the optional adapter.
2
Refer to the installation or service manual on how to use
BS1~BS3 push buttons, and DS1+DS2 DIP switches.
3
Do not operate the unit by short-circuiting protection device
S1PH.
4
For connection of INDOOR-OUTDOOR F1-F2 transmission
wiring, and OUTDOOR-OUTDOOR F1-F2 transmission
wiring, refer to the service manual.
Legend for wiring diagram 8 HP:
A1P
Printed circuit board (main)
A2P
Printed circuit board (noise filter)
A3P
Printed circuit board (inverter)
A4P
Printed circuit board (cool/heat selector)
BS*
Push button (mode, set, return) (A1P)
C*
Capacitor (A3P)
DS*
DIP switch (A1P)
E1HC
Crankcase heater
F*U
Fuse (T 3.15 A / 250 V) (A1P)
F3U
Field fuse
F400U
Fuse (T 6.3 A / 250 V) (A2P)
F410U
Fuse (T 40 A / 500 V) (A2P)
F411U
Fuse (T 40 A / 500 V) (A2P)
F412U
Fuse (T 40 A / 500 V) (A2P)
HAP
Running LED (service monitor green) (A1P)
K1M
Magnetic contactor (A3P)
K*R
Magnetic relay (A*P)
L1R
Reactor
M1C
Motor (compressor)
M1F
Motor (fan)
PS
Power supply (A1P, A3P)
Q1DI
Earth leakage circuit breaker (field supply)
Q1RP
Phase reversal detect circuit (A1P)
R21T
Thermistor (M1C discharge)
R3T
Thermistor (accumulator)
R5T
Thermistor (subcool liquid pipe)
R6T
Thermistor (heat exchanger gas pipe)
R7T
Thermistor (suction)
R*
Resistor (A3P)
S1NPH
High pressure sensor
S1NPL
Low pressure sensor
S1PH
High pressure switch (discharge)
S1S
Air control switch (optional)
S2S
Cool/heat selector switch (optional)
Installation and operation manual
44
SEG1~SEG3 7-segment display
T1A
Earth leakage detector
V1R
IGBT power module (A3P)
V2R
Diode module (A3P)
X37A
Connector (power supply for option PCB) (optional)
X66A
Connector (cool/heat selector switch) (optional)
X1M
Terminal strip (power supply)
X*A
PCB connector
X*M
Terminal strip on PCB (A*P)
X*Y
Connector
Y2E
Electronic expansion valve
Y1S
Solenoid valve (4‑way valve)
Z*C
Noise filter (ferrite core)
Z*F
Noise filter
21
Disposal
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
VRV IV compressor unit for indoor installation
RKXYQ5T8 + RKXYQ8T7Y1B
4P499900-1A – 2020.10