CHANGING THE ADDITIONAL MIDDLE POSITION

To change the additional middle position repest the procedure described in the previous
section.

DELETING THE ADDITIONAL MIDDLE POSITION

Carry out the following command sequence in order to cancel the additional middle
position:
Tn: Already programmed remote control
+
B
C
Tn

SHORT-TERM SETTING OF A REMOTE CONTROL

This function makes it possible to store a remote control temporarily, for example, with the
purpose of setting the limit switches during assembly in the factory. A later final saving
of the remote control will be possible using the appropriate command sequence (see:
"SETTING THE FIRST REMOTE CONTROL"). The operations described below can be carried
out only when the motor has just come out of the factory or after a full memory clearing
(see: "FULL MEMORY CLEARING"). The motor makes the following operations possible
only within the time limits described in order to make sure that the short-term setting is
used only in the installation or factory setting phase and not during daily use.
Power up the motor, make sure that no other motors having an empty memory are
powered up in the same operating range.
Within 30 seconds after start, press the B and C buttons simultaneously until the motor
gives a confirmation signal.
The remote control will remain stored for 5 minutes, while the motor is powered up.
After 5 minutes or when the motor has its power cut off, the remote control will be
cancelled.
T1: First remote control to be set
B
B
B
+
C
+
C
T1
Tn
38
A
Tn (2 sec)