Auxiliary Current Consumption; Tightening Torques; Electrical Connections; Mechanical Connections - ABB ACS880-304 +A003 Series Hardware Manual

Diode supply modules
Table of Contents

Advertisement

146 Technical data

Auxiliary current consumption

Device
Control unit ZCU-14 with options
D6D module fan (DOL +C188)
G2E140-PE77-XX
D7D module fan (DOL +C188)
R2E225-RA92-17
D8D module fan (DOL +C188)
D3G146-AH50-16
D6D/D7D cabinet fan W2E143-AA09-
01
Definitions
I
Nominal current consumption
N
I
Maximum current consumption
max
I
Starting current consumption
start

Tightening torques

Unless a tightening torque is specified in the text, the following torques can be used.

Electrical connections

Size
M3
0.5 N·m (4.4 lbf·in)
M4
M5
M6
M8
M10
M12
M16
120 N·m (90 lbf·ft)

Mechanical connections

Size
M5
M6
10 N·m (7.4 lbf·ft)
M8
24 N·m (17.7 lbf·ft)

Insulation supports

Size
M6
U
N
V
24 V DC
±10%
230 V AC
230 V AC
230 V AC
230 V AC
Torque
1 N·m (9 lbf·in)
4 N·m (35 lbf·in)
9 N·m (6.6 lbf·ft)
22 N·m (16 lbf·ft)
42 N·m (31 lbf·ft)
70 N·m (52 lbf·ft)
Max. torque
6 N·m (53 lbf·in)
Max. torque
5 N·m (44 lbf·in)
f
I
max
Hz
A
-
2.05
0.46 (50 Hz) /
50 / 60
-
0.68 (50 Hz) /
50 / 60
-
1.20 (50 Hz) /
50 / 60
-
0.10 (50 Hz) /
50 / 60
-
Note
Strength class 4.6...8.8
Strength class 4.6...8.8
Strength class 8.8
Strength class 8.8
Strength class 8.8
Strength class 8.8
Strength class 8.8
Strength class 8.8
Note
Strength class 8.8
Strength class 8.8
Strength class 8.8
Note
Strength class 8.8
I
I
N
start
A
A
-
-
0.92 (50 Hz) /
0.62 (60 Hz)
1.24 (60 Hz)
1.36 (50 Hz) /
0.92 (60 Hz)
1.84 (60 Hz)
2.40 (50 Hz) /
1.62 (60 Hz)
3.42 (60 Hz)
0.20 (50 Hz) /
0.14 (60 Hz)
0.27 (60 Hz)

Advertisement