22
confIguratIon
34.
This parameter determines to which alarm frames and how the
device should react. The parameters consist of 4 bytes, three most
significant bytes are set according to the official Z-Wave protocol
X – channels summarized: 1/2/3/4 channel are equal to values
1/2/4/8. Y – sequence number: 1-10 (parameter 157).
Parameter size 4B
Default value
Available
values
35.
This parameter determines duration of alarm signalization.
Parameter size 2B
Default value
Available
values
40.
This parameter defines which actions result in sending scene ID
and attribute assigned to them. Parameter is relevant only if pa-
Parameter size 1B
Default value
Available
values
Alarm configuration - 5th slot
specification.
0 (default)
1B [MSB] – Notification Type
2B – Notification Value
3B – Event/State Parameters
4B [LSB] – action:
0x00 – No reaction
0x0X – Turn off selected channel
0x1X – Turn on the load
0x2X – Turn off the load
0x3Y – Load blinking
Duration of alarm signalization
600 (10min)
0 – infinite signalization
1-32400 (1s-9h, 1s step)
Input 1 - sent scenes
rameter 20 is set to 2, 3 or 4.
0 (no scenes sent)
1 – Key pressed 1 time
2 – Key pressed 2 times
4 - Key pressed 3 times
8 – Key hold down and key released