HUAWEI NE40E-X1 & NE40E-X2 Universal Service
Router
Hardware Description
Item
Cable
4.2 Chassis and Cabinet Grounding Cable
This section describes the structure and technical specifications of the chassis and cabinet ground
cable.
4.2.1 Introduction
The chassis and cabinet ground cables are used to ground a chassis and a cabinet. Before the
delivery of a device, ground cables are correctly connected to the front, back and side doors of
the cabinet.
4.2.2 Structure
The connector of the chassi and cabinet ground cable is the same as the connector of the DC-
input power cable.
4.2.3 Technical Specifications
Table 4-3
Table 4-3 Technical specifications of the NE40E-X1 and cabinet ground cable
Item
PGND cable
Fireproof class
Table 4-4
Issue 02 (2011-09-10)
Description
Naked Crimping Terminal,OT,10mm^2,M8,Tin Plating,Naked Ring
Terminal
Power Cable,-450/750V,H07Z-K UL3386,10mm^2,Blue,Low Smoke Zero
Halogen Cable
Power Cable,-450/750V,H07Z-K UL3386,10mm^2,Black,Low Smoke
Zero Halogen Cable
lists the technical specifications of the NE40E-X1 and cabinet ground cable..
Terminal
Cable type
lists the technical specifications of the NE40E-X2 and cabinet ground cable..
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
Naked Crimping Terminal,OT,6mm^2,M4,Tin
Plating,Naked Ring Terminal
Power Cable,-450/750V,H07Z-K UL3386,6mm^2,oli-
vine
CM
4 Cables
75