4.2.4 Double spray lance,
pressure regulation
4.2.5 Stop
Original Instructions
hot water does not have to pass
through the high pressure pump
the maximum temperature can
be as high as 99°C.
If an error occurs to the heating
system of the machine, the ma-
chine stops and the red "STOP"
push button (4) will start fl ash-
ing and the heating source
will be shut off. Press the red
button to re-set the machine.
1
min.
max.
By pushing the green "START"
push button (3), the machine
will continue to be functional
with non heated water.
In this case please refer to sec-
tion "7 Troubleshooting".
The spray lance features 2
nozzles, a high pressure nozzle
and a low pressure nozz le.
High pressure mode
When the pressure reducing
valve (1) is completely closed
(turned clockwise - B), only the
high pressure nozzle is used -
high pressure mode.
Low pressure mode
When the reducing valve (1)
is completely opened (turned
counterclockwise - A), both
spray lances are used - low
pressure mode / possibility of
dosing detergents.
The pres sure may be reg u lat ed
between these positions.
Danger of scalding!
Never detach high pressure
hoses at a water temperature
above 50°C.
Prior to dismounting of the high
pressure hose, the machine
should be cooled down. After
cooling down, stop the machine
and close the shut-off cock.
Never detach the high pressure
hose while the machine is in
operation.
SH SOLAR E, D
17