Automatic Feeder Cutoff
The Automatic Feeder Cutoff monitors the speed of the feeder pivot shaft. Any time the feeder pivot shaft speed
drops below 210 RPM, power to the feeder clutch solenoid will be shut off. The feeder indicator on the shaft speed
monitor will illuminate and the audible warning will sound. The feeder will remain shut off until the feeder clutch
switch is turned OFF and ON.
NOTE: There is a five (5) second delay at start up to allow the feeder to reach operating speed before the feeder
cutoff starts to monitor the shaft speed.
Bypass Automatic Feeder Cutoff
The Automatic Feeder Cutoff can be bypassed to provide standard operation of the feeder clutch.
To bypass the Automatic Feeder Cutoff, refer to Change Mode in Operating Instructions in this manual.