netvox R718E User Manual page 6

Wireless three-axis digital accelerometer & ntc thermistor
Hide thumbs Also See for R718E:
Table of Contents

Advertisement

Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v, Acceleratedvelocitychange = 1m/s2
Downlink: 011C003C003C0100010000
Device returns:
811C000000000000000000 (configuration is successful)
811C010000000000000000 (configuration failed)
Read device parameters
Downlink: 021C000000000000000000
Device returns:
821C003C003C0100010000 (current device parameters)
Example of threshold configuration:
Description
Device
SetActiveThresholdReq
SetActiveThresholdRsp
R718E
GetActiveThresholdReq
GetActiveThresholdRsp
Assuming that the Active Threshold is set to 10m/s
configured as 16.
Assuming that the InActive Threshold is set to 8m/s
configured as 13.
Configure device parameters ActiveThreshold=16, InActiveThreshold=13
Downlink: 031C0010000D0000000000
Device returns:
831C000000000000000000 (configuration is successful)
831C010000000000000000 (configuration failed)
Read device parameters
Downlink: 041C000000000000000000
Device returns:
841C0010000D0000000000 (device current parameter)
Min Interval
Max Interval
(Unit:second)
(Unit:second)
Any
number
between
Any number between
1~65535
1~65535
CmdID
DeviceType
ActiveThreshold
0x03
(2Bytes)
Status
0x83
(0x00_success)
0x1C
0x04
ActiveThreshold
0x84
(2Bytes)
2
, the value to be set is 10/9.8/0.0625=16.32,and the last value obtained is an integer and is
2
, the value to be set is 8/9.8/0.0625=13.06, and the last value obtained is an integer and is
Reportable
Change
Can not be 0.
NetvoxPayLoadData
InActiveThreshold
(2Bytes)
InActiveThreshold
(2Bytes)
Current
Current
Change≥
Reportable Change
Reportable Change
Report
Report
per Min Interval
per Max Interval
6
Reserved
(5Bytes,Fixed 0x00)
Reserved
(8Bytes,Fixed 0x00)
Reserved
(9Bytes,Fixed 0x00)
Reserved
(5Bytes,Fixed 0x00)
Change