6 Shut Down Sensor and Tec Case

6 Shut Down Sensor and Tec Case
Multi Sensor or RF-100 breaks
By disconnecting the cable or shut down the Tec Case without shut down the sensor, the
sensor could break.
Always shut down the sensor in the DT Control Center before disconnecting the cable
or shut down the Tec Case.
Procedure:
Connect to the DT Control Center.
1
Choose menu OPTIONS > Site Configuration.
2
For each connected Multi Sensor and RF-100, right-click on the sensor symbol and
3
choose System > Shutdown Hardware.
In the header the message Network error, reconnecting... is shown.
The light of the blue button at the Multi Sensor or RF-100 turns off.
Push the blue button at the outside of the Tec Case.
4
The light of the blue button at the Tec Case turns off and the Tec Case is off.
Disconnect all cables from the Tec Case and the sensors.
5
Push the blue button inside the Tec Case.
6
The battery display in the Tec Case turns off and the Tec Case is shut down.