Floor Heating Setting - HDL Prism Pro User Manual

Multi-function touch panel
Table of Contents

Advertisement

Select "Floor heating" label in the panel configuration page, as shown in Figure 5-1.
The setting items are explained below:
① Device information: to select the working mode and control mode of floor heating.
Working mode includes "Floor Heating/Floor Cooling/Auto" and control mode includes
"Slave Control" and "Fully control".
➢ Slave control: to control up to 6 objects via switching objects.
➢ Fully control: fully control can set up to 4 floor heating channels and 4 floor cooling
channels.
② Temperature sensor: when "Fully control" is selected, the actual working modes should
depend on the temperature.
➢ Inner sensor: the panel refers to temperature data from internal sensor.
➢ Read from bus: the panel refers to external temperature. If selecting "Receive
HDL Automation Co., Ltd.
http://www.hdlchina.com
Prism Pro/Multi-function Touch Panel User Manual

5 Floor Heating Setting

Figure 5-1 Floor heating setting
21